Summary of Contents for Zeta Alarm Systems Premier Quatro QT/4P
Page 1
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) Firmware Versions: PANEL 1.84 & LOOP CARD 3.70 MKII PROTOCOL ONE TO FOUR LOOPS ANALOGUE ADDRESSABLE FIRE ALARM PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK www.acornfiresecurity.com...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) TABLE OF CONTENTS WHAT TO DO IF THE FIRE ALARM PANEL SHOWS A FAULT (YELLOW LED) ....................2 1. FIRE ALARM CONTROL PANEL SAFETY ISSUES ............................. 3 2. THE PURPOSE OF A FIRE ALARM SYSTEM ............................3 3.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) WHAT TO DO IF THE FIRE ALARM PANEL SHOWS AN ALARM (RED LED) Write down the LCD reading and which LEDs are lit (either in the log book, or on a piece of paper for transferring to the log book later).
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 1. FIRE ALARM CONTROL PANEL SAFETY ISSUES When the Premier Quatro panel is operating normally, i.e. not being tended by service personnel, the access door must be closed and locked.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 3. USER RESPONSIBILITIES & MAINTAINENCE OF THE FIRE ALARM SYSTEM, INCLUDING THE FACP & ITS INTEGRAL PSE According to the British Standard Code for Fire Detection and Alarm Systems for Commercial Buildings (BS 5839-1:2002+A2:2008), the owner or person having control of the premises should appoint a responsible person to oversee the effective operation of the Fire Alarm System (Clause 47.1).
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) Annual Test (to be carried out by authorised service personnel only) Check every detector, call point, sounder and all auxiliary equipment for correct operation. Check Switch Mode cage INPUT Voltage (30.5 VAC), Charger Voltage (27.6V off load, adjusted with VR1) & Battery Voltage (25-27V) Every Five Years (to be carried out by authorised service personnel only) ...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 4. PANEL INDICATIONS & CONTROLS 4.1 PANEL INDICATIONS The LEDs used for zonal fire indication are reserved solely for this purpose. The other LEDs in this zonal range are shared between fault, disable and test.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) The only functions that can be performed by the user when the panel is in the normal or quiescent state are: Ending a programmed delay when the panel is in alarm. For example, if the installation engineer has instructed the panel to wait for 2 minutes after a fire has been detected before sounding the alarm, a user can override this delay if it is obvious that the building needs to be evacuated immediately.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 5. THE FIRE CONDITION 5.1 HOW THE QUATRO INDICATES AN ALARM When the Panel is set into alarm by a Detector or Manual Call Point located in a zone that is not already in alarm it will: - ...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 5.4 TURNING ON THE ALARM SOUNDERS FROM THE FACP (TO EVACUATE THE BUILDING) If a user comes across a fire in the protected building, the alarm can also be raised by operating the START / STOP SOUNDERS button on the front of the Fire Alarm Control Panel.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 6. THE FAULT CONDITION The fire alarm panel monitors itself, and any equipment connected to it, for any faults that can occur. If a fault occurs, the panel responds by activating its Internal buzzer and lighting the General Fault light and any other Fault light(s) relevant to the particular fault.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) SYSTEM FAULT The System Fault LED lights when the Panel’s micro-processor has reset, typically after excessive electrical interference, or if the contents of its memory have been corrupted. EARTH FAULT The Earth Fault LED lights when the panel detects an earth fault (short circuit to earth) on the wiring to any part of the control panel.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 7. DISABLEMENTS 7.1 REASONS FOR DISABLING CERTAIN PARTS OF A FIRE ALARM SYSTEM Certain parts of this Fire Alarm Panel can be temporarily disabled (i.e. switched off) to suit prevailing conditions. For example, if there is a risk of a False Alarm in a zone, for example, from vehicle exhaust smoke in a loading bay, it is possible for the user to disable that zone during the risk period and then enable it again afterwards.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 8. SYSTEM DESCRIPTION FIRE ALARM SYSTEM SUMMARY FIRE ZONE INFORMATION ZONE DESCRIPTION NO. OF NO. OF ZONE NO. LOOP NO. NO. OF MCPS NO. OF I/OS A brief description of all the rooms and areas DETECTORS SOUNDERS contained in each zone.
Page 15
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ZONE DESCRIPTION NO. OF NO. OF ZONE NO. LOOP NO. NO. OF MCPS NO. OF I/OS A brief description of all the rooms and areas DETECTORS SOUNDERS contained in each zone. PAGE 14 #Doc No.
Page 16
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ZONE DESCRIPTION NO. OF NO. OF ZONE NO. LOOP NO. NO. OF MCPS NO. OF I/OS A brief description of all the rooms and areas DETECTORS SOUNDERS contained in each zone. PAGE 15 #Doc No.
Page 17
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ZONE DESCRIPTION NO. OF NO. OF ZONE NO. LOOP NO. NO. OF MCPS NO. OF I/OS A brief description of all the rooms and areas DETECTORS SOUNDERS contained in each zone. PAGE 16 #Doc No.
Page 18
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ZONE DESCRIPTION NO. OF NO. OF ZONE NO. LOOP NO. NO. OF MCPS NO. OF I/OS A brief description of all the rooms and areas DETECTORS SOUNDERS contained in each zone. PAGE 17 #Doc No.
Page 19
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ZONE DESCRIPTION NO. OF NO. OF ZONE NO. LOOP NO. NO. OF MCPS NO. OF I/OS A brief description of all the rooms and areas DETECTORS SOUNDERS contained in each zone. PAGE 18 #Doc No.
Page 20
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ZONE DESCRIPTION NO. OF NO. OF ZONE NO. LOOP NO. NO. OF MCPS NO. OF I/OS A brief description of all the rooms and areas DETECTORS SOUNDERS contained in each zone. SOUNDER CIRCUIT INFORMATION SOUNDER CIRCUIT DESCRIPTION SOUNDER CIRCUIT...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) DETAILED LOOP CONTENTS: LOOP 1 This must be fully recorded by an authorised Engineer before system handover. (A Loop Report from the Quatro Connect Configuration software will also be acceptable) ADDR ZONE TYPE...
Page 22
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL PAGE 21 #Doc No. GLT-215-7-2 Issue: 1.08 Author: TE/NJ Date: 26/05/2017 www.acornfiresecurity.com...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) DETAILED LOOP CONTENTS: LOOP 2 This must be fully recorded by an authorised Engineer before system handover. (A Loop Report from the Quatro Connect Configuration software will also be acceptable) ADDR ZONE TYPE...
Page 24
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL PAGE 23 #Doc No. GLT-215-7-2 Issue: 1.08 Author: TE/NJ Date: 26/05/2017 www.acornfiresecurity.com...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) DETAILED LOOP CONTENTS: LOOP 3 This must be fully recorded by an authorised Engineer before system handover. A Loop Report from the Quatro Connect Configuration software will also be acceptable) ADDR ZONE TYPE...
Page 26
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL PAGE 25 #Doc No. GLT-215-7-2 Issue: 1.08 Author: TE/NJ Date: 26/05/2017 www.acornfiresecurity.com...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) DETAILED LOOP CONTENTS: LOOP 4 This must be fully recorded by an authorised Engineer before system handover. A Loop Report from the Quatro Connect Configuration software will also be acceptable) ADDR ZONE TYPE...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL ADDR ZONE TYPE LABEL PAGE 27 #Doc No. GLT-215-7-2 Issue: 1.08 Author: TE/NJ Date: 26/05/2017 www.acornfiresecurity.com...
Page 29
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 9. FIRE ALARM LOG BOOK It is recommended that this LOG BOOK section of the Manual be maintained by the responsible person(s) on site, who should ensure every event is properly recorded (including fire alarm conditions, failures, tests, temporary disconnections, disablements, enablement’s, dates of installing engineers’...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) MAINTENANCE WORK LOOP & ZONE/ ADDITIONAL WORK DATE TIME REASON FOR WORK WORK CARRIED OUT SIGNED ADDRESS LOCATION REQUIRED PAGE 29 #Doc No. GLT-215-7-2 Issue: 1.08 Author: TE/NJ Date: 26/05/2017 www.acornfiresecurity.com...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) MAINTENANCE WORK (CONTINUED) LOOP & ZONE/ DATE TIME REASON FOR WORK WORK CARRIED OUT ADDITIONAL WORK REQUIRED SIGNED ADDRESS LOCATION PAGE 30 #Doc No. GLT-215-7-2 Issue: 1.08 Author: TE/NJ Date: 26/05/2017 www.acornfiresecurity.com...
Page 32
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) UNWANTED (FALSE) ALARMS CAUSE (IF MAINTENANCE FURTHER LOOP & ZONE/ KNOWN) OR MAINTENAN CATEGORY OF DATE TIME VISIT NEEDED ACTION SIGNED ADDRESS LOCATION ACTIVITIES IN CE FINDINGS FALSE ALARM (YES/NO) REQUIRED ALARM AREA...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) UNWANTED (FALSE) ALARMS (CONTINUED) CAUSE (IF MAINTENANCE FURTHER LOOP & ZONE/ KNOWN) OR MAINTENAN CATEGORY OF DATE TIME VISIT NEEDED ACTION SIGNED ADDRESS LOCATION ACTIVITIES IN CE FINDINGS FALSE ALARM (YES/NO) REQUIRED...
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ALL EVENTS OTHER THAN MAINTENANCE WORK OR FALSE ALARMS DETAILS OF EVENT DATE LOOP & ZONE/ DATE TIME (INCLUDING CAUSE IF ACTION REQUIRED COMPLET INITIALS ADDRESS LOCATION KNOWN) PAGE 33 #Doc No.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) ALL EVENTS OTHER THAN MAINTENANCE WORK OR FALSE ALARMS (CONTINUED) DETAILS OF EVENT LOOP & ZONE/ DATE DATE TIME (INCLUDING CAUSE IF ACTION REQUIRED INITIALS ADDRESS LOCATION COMPLETED KNOWN) PAGE 34 #Doc No.
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) 10. COMMISSIONING THE SYSTEM, INCLUDING POWER SUPPLY EQUIPMENT P.S.E. The commissioning of this fire alarm system should be performed by a qualified commissioning engineer, who has an understanding of sections 2, 3, &...
Page 37
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) Design Certificate (Page 1 of 2) Certificate of DESIGN for the Premier Quatro Fire Alarm System installed at: ADDRESS: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the design of the fire alarm system, particulars of which are set out below, CERTIFY that the said design for which I/we have been responsible complies to the best of my/our knowledge and belief with the recommendations of section 2 of BS 5839-1:2013 for the system category described below, except for the variations, if any,...
Page 38
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) Design Certificate (Page 2 of 2) Measures incorporated to limit false alarms. Account has to be taken of the guidance contained in section 3 of BS 5839-1:2013 and, more specifically (tick as appropriate): The System is manual.
Page 39
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) Installation Certificate Certificate of INSTALLATION for the Premier Quatro Fire Alarm System installed at: ADDRESS: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the installation of the fire alarm system, particulars of which are set out below, CERTIFY that the said installation for which I/we have been responsible complies to the best of my/our knowledge and belief with the specifications described below, and with the recommendations of BS 5839-1:2013, except for the...
Page 40
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) Commissioning Certificate Certificate of COMMISSIONING for the Premier Quatro Fire Alarm System installed at: ADDRESS: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the commissioning of the fire alarm system, particulars of which are set out below, CERTIFY that the said work for which I/we have been responsible complies to the best of my/our knowledge and belief with the recommendations of Clause 39 of BS 5839-1:2013, except for the variations, if any, stated in this certificate...
Page 41
www.acornfiresecurity.com PREMIER QUATRO USER MANUAL, MAINTENANCE GUIDE & LOG BOOK (Fyreye MKII) Acceptance Certificate Certificate of ACCEPTANCE for the Premier Quatro Fire Alarm System installed at: ADDRESS: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the acceptance of the fire alarm system, particulars of which are set out below, ACCEPT the system on behalf Name ( Position:...
Need help?
Do you have a question about the Premier Quatro QT/4P and is the answer not in the manual?
Questions and answers