Preoperational Test - ADC AD-575 Installation Manual

Hide thumbs Also See for AD-575:
Table of Contents

Advertisement

labels attached to the dryer.
2.
Check incoming supply voltage to be sure that it is
the
same
as
indicated
on
the
dryer
data
label
located in the right-hand control cabinet.
3.
Check
to assure that the dryer is connected to the
type of heat/gas indicated on the dryer data label.
4.
The
sail
switch damper assembly is installed on gas
dryers
and
pre-adjusted
at
the
factory
prior to
dryer shipment.
However, the sail
switch adjustment
must be checked to assure that this important safety
controlisfunctioning.
5.
Check
bolts,
nuts,
screws,
for security.
terminals,
and
fittings
6.
Be
sure
all
gas
shut-off
position.
valves
are
i n the open
7.
Be sure all back guard panels and service
have been replaced.
box covers
8.
Rotate the tumbler
(drum)
by hand to
be
sure it
moves freely.
E.
Preoperational
Test
All
dryers
are
thoroughly
tested
and
inspected
before
leaving the factory.
However,
a preoperational
test
should
be taken before the dryer is publicly used.
It
is possible
that adjustments have changed in transit.
1.
Turn on electric power to dryer.
2.
Refer
to
the
operating
instructions
in
the
AD-575
Service
Manual
(P / N
450105)
for
starting
your
particular model dryer.
3.
Start dryer.
Using a "high heat" selection, accumu¬
late about 20 minutes of time.
4.
Remove air from the gas line.
Run the dryer about 5
minutes.
If the burner does not ignite during these
5
minutes,
turn
the
dryer
off
and
wait
a
few
minutes.
NOTE:
The
dryer
has
a
safety
device
(flame
sensor)
which
shuts
off
the
gas
if
the
burner does
not
ignite in a short time.
Wait
a few minutes for
this safety device to reset.
9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AD-575 and is the answer not in the manual?

Table of Contents