Modular residual current device type b for additional protection (protection against indirect contact) in earthed systems (tn and tt systems) (20 pages)
HMI140 / HMI145 / HMI150 Table of contents General information................... 5 How to use the manual..........................5 Indication of important instructions and information...............5 Signs and symbols............................5 Service and Support............................5 Training courses and seminars........................6 Delivery conditions............................6 Inspection, transport and storage......................6 Warranty and liability.............................6...
Page 4
Table of contents Declarations of conformity........................21 Ordering information...........................21 HMI1xx_D00481_00_M_XXEN/11.2023...
Protect from dust Temperature range Recycling RoHS directives Service and Support Information and contact details about customer service, repair service or field service for Bender devices are available on the following website: Fast assistance | Bender GmbH & Co. KG. HMI1xx_D00481_00_M_XXEN/11.2023...
Regular face-to-face or online seminars for customers and other interested parties: www.bender.de > know-how > seminars. Delivery conditions The conditions of sale and delivery set out by Bender GmbH & Co. KG apply. These can be obtained in printed or electronic format. The following applies to software products: ‘Software clause in respect of the licensing of standard software as part of deliveries,...
HMI140 / HMI145 / HMI150 Disposal of Bender devices Abide by the national regulations and laws governing the disposal of this device. For more information on the disposal of Bender devices, refer to www.bender.de > service & support. 1.10 Safety If the device is used outside the Federal Republic of Germany, the applicable local standards and regulations must be complied with.
Device-specific safety instructions Device-specific safety instructions ADVICE The HMI1xx complies with the relevant harmonized standards to ensure that the requirements of the Radio Equipment Directive (see chapter “Declarations of conformity”, page 21) are met. It is the responsibility of the distributor of the complete system to ensure conformity with this and any additional legal requirements.
USB cable. The module must only be used in combination with charge controllers* from Bender GmbH & Co. KG that support the operation of the HMI module. Any other use than that described in this manual is regarded as improper.
Function 3.3.2 Sensors An integrated light sensor is provided to enable adaptation of the light intensity of the LEDs to the brightness of the surroundings. The HMI module is equipped with an integrated temperature sensor to avoid any thermal damage. The sensors are read and the corresponding reaction takes place via the charge controller that is connected.
HMI140 / HMI145 / HMI150 USB host outputs The two USB host outputs of the HMI module are connected to a USB host output of the charge controller via an internal USB hub. They support communication or data exchange in accordance with the functional description of the charge controller in use.
HMI140 / HMI145 / HMI150 Mounting Ambient light sensor Temperature sensor Red marks: possible fastening points Either the inner or the outer fastening holes can be used. Fastening recommendation, Ø3.1: • Screws: 2.5 mm • Head: max. 5 mm • Extension studs: 5.1 mm •...
Connection Connection Definition of connections Terminal Description USB type A: 2 x USB host USB type B: Charge controller (controller interface, 5 V supply) Phoenix Contact PCB terminal, 8-pole: Additional DC supply, FE, relay switching contacts, control input Phoenix Contact PCB terminal, 8-pole: External RGB LEDs LEDs can be connected without series resistors (constant current control) Voltage supply connection...
HMI140 / HMI145 / HMI150 Connection assignment, terminals C and D Terminal C: Phoenix Contact DMC 1.5/ 4-G1-3.5 P26THR R44 (2x4-pole) Description Description DC supply voltage input Ground of the voltage supply and control signals Functional earthing FE input (EMC functional earthing)
Page 16
Connection Examples for connecting the external RGB LED outputs Example 2: Example 1: LED Two LEDs per with shared channel with cathode shared anode HMI1xx_D00481_00_M_XXEN/11.2023...
HMI140 / HMI145 / HMI150 Commissioning It is preferable to operate the HMI module with a DC supply voltage to prevent overloading of the USB supply. ADVICE If supply of the HMI module is possible exclusively via the USB interface, the availability of individual...
Voltage range Max. power consumption without USB load 3.5 / 7.5 / 9.5 W HMI140 / 145 / 150 Max. power consumption with USB load HMI145 / 150 14.0 / 16.0 W DC 5 V from charge controller (terminal B)
Technical data Transport (IEC 60721-3-2) Long-term storage (IEC 60721-3-1) 1M12 EMC environmental classes Emitted interference B (residential, business or commercial areas) Interference immunity A (industrial environment) Connection lengths / cable types USB host A1 and A2 Max. cable length 1.8 m Cable type Double shielded Charge controller connection (terminal B)
Page 21
Declarations of conformity EU Declaration of conformity Hereby, Bender GmbH & Co. KG declares that the device covered by the Radio Directive complies with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following Internet address: https://www.bender.de/fileadmin/content/Products/CE/CEKO_HMIxxx.pdf...