directly proportional to the velocity of conductive liquid, magnetic flux density and width of conductor
(interior diameter of flowmeter). Such induced electromotive force is detected by a pair of electrodes on
the tube wall of the flowmeter, and the equation of induced electromotive force is as follows:
U = K×B×V×D
U: Induced electromotive force
K: Instrument Constant
B: Magnetic flux density
V: Velocity
D: Interior diameter of measuring pipe
Figure 1 working principle diagram
4 Product Category
Flange Type (carbon steel)
Flange Type (stainless steel)
Threaded Type (stainless steel)
Threaded Type
Clamping Type
Battery Supplied Type (carbon steel)
attery Supplied Type (stainless steel)
B
2
Need help?
Do you have a question about the MFE600E and is the answer not in the manual?
Questions and answers