8 - Properties
8..11
Baud Rate
12..15
Reserved
This property is stored in non-volatile memory, so it persists when the device is power cycled. When this
property is changed, the device must be reset (see Command 0x02 - Reset Device) or powered off for at
least 30 seconds, then powered on, before the changes will take effect.
Example Set Request (Hex)
Cmd Num
01
Example Set Response (Hex)
Result Code
00
Example Get Request (Hex)
Cmd Num
00
Example Get Response (Hex)
Result Code
00
mDynamo| OEM Secure Card Reader Authenticator | Programmer's Manual (COMMANDS)
This field specifies the baud rate of the SPI port.
0 = 9375 baud
1 = 18750 baud
2 = 37500 baud
3 = 75000 baud
4 = 150000 baud
5 = 300000 baud
6 = 600000 baud
7 = 1200000 baud
8 = 2400000 baud
9 = 4800000 baud.
These bits should always be written as zeroes.
Data Len
03
00
01
02
Page 119 of 167 (D998200151-200)
Property ID
6A
Data Len
Data Len
Data Len
Data
03 11 (default)
Data
Property ID
6A
Data
03 11 (default)