Advertisement

Quick Links

LECTUS secure
ARD‑SIGR20‑SEO | ARD‑SIGR20‑ICL | ARD‑SIGR20K‑ICL |
ARD‑SIGR40‑ICL | ARD‑SIGR40K‑ICL
en
Installation manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LECTUS secure ARD-SIGR20-SEO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bosch LECTUS secure ARD-SIGR20-SEO

  • Page 1 LECTUS secure ARD‑SIGR20‑SEO | ARD‑SIGR20‑ICL | ARD‑SIGR20K‑ICL | ARD‑SIGR40‑ICL | ARD‑SIGR40K‑ICL Installation manual...
  • Page 3: Table Of Contents

    Wiegand readers Data security of Wiegand interface RFID technology Reading distances Installation Choosing the installation location Installing data and supply lines Assembly preparation Assembling the reader Care instructions Decomissioning Technical specifications Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 4: Safety

    (limit switches, protective equipment, etc.). Notice! Installation and assembly of electrical components must be carried out by a qualified electrician. 2024-04 | V01 | Bosch Security Systems B.V. Installation manual...
  • Page 5: Fcc Compliance

    - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 6: Short Information

    | Short information LECTUS secure Short information Introduction This installation manual is aimed at authorized service providers. It contains instructions on the installation and configuration of the Bosch Security Systems proximity reader LECTUS secure. Parts included Quantity Component Reader module...
  • Page 7: Wiegand Readers

    Direct mounting on metal might reduce the optimal reading distance. Reading distance (cm) iCLASS ISO iCLASS ISO key Seos ISO card Seos key fob card ARD-SIGR20-ICL 11 cm 6 cm 4 cm 3 cm Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 8 Metal in the "active" effective area of the HF field. The transmission energy is attenuated. This point is particularly relevant when installing the reader components in metal front panels (including metal columns, etc.). 2024-04 | V01 | Bosch Security Systems B.V. Installation manual...
  • Page 9: Installation

    Lay the connection cables according to the local conditions and prepare them for connection. Remove the two 5-pin plug-in terminal from the reader module and connect the wires according to the Wiring diagram. Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 10: Assembling The Reader

    Assembling the reader Notice! Install the reader on a flat, stable surface. Failure to do so may compromise the IP rating and/or tamper feature. 2024-04 | V01 | Bosch Security Systems B.V. Installation manual...
  • Page 11 Hook the upper part of the reader on the top of the mounting plate. Push the bottom of the reader to the wall until it is inside the mounting plate. Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 12 To test if the reader is working properly: Power the reader. The reader beeps and the LED flashes. Present a credential in front of the reader. The reader beeps and the LED flashes. 2024-04 | V01 | Bosch Security Systems B.V. Installation manual...
  • Page 13: Care Instructions

    Harsh detergents can damage or discolor the surface. Do not use cleaning agents with mechanical effects, such as scouring milk and scouring sponge. Only clean the reader with a soft, damp cloth and only use clear water. Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 14: Decomissioning

    This product and/or battery must be disposed of separately from household waste. Dispose such equipment according to local laws and regulations, to allow their reuse and/or recycling. This will help in conserving resources, and in protecting human health and the environment. 2024-04 | V01 | Bosch Security Systems B.V. Installation manual...
  • Page 15: Technical Specifications

    121.5 mm x 45 mm x 19.5 mm Dimensions (H x W x D) (in) 4.78 in x 1.77 in x 0.77 in Material Polycarbonate Mounting type Surface-mounted; Mullion-mounted Weight (g) 75 g Weight (oz) 2.65 oz Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 16 Weight (g) 140 g Weight (oz) 4.94 oz Operation ARD-SIGR20-SEO Card reader, R20, SEOS, Wiegand Keypad LED indication Multi-color Credential type Cards/keyfobs/tokens Wireless transmission frequency 13.56 MHz Reading format Seos 2024-04 | V01 | Bosch Security Systems B.V. Installation manual...
  • Page 17 SE; Seos ARD-SIGR40K-ICL Card reader w/ kp, R40, iCLASS, Wiegand Keypad LED indication Multi-color Credential type Cards/keyfobs/tokens; PIN Wireless transmission frequency 13.56 MHz Reading format iCLASS; iCLASS SE; Seos Bosch Security Systems B.V. 2024-04 | V01 | Installation manual...
  • Page 18 | Technical specifications LECTUS secure 2024-04 | V01 | Bosch Security Systems B.V. Installation manual...
  • Page 20 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2024 Building solutions for a better life 202405211555...

Table of Contents