Bosch LECTUS select ARD‑SELECT‑BP Installation Manual
Bosch LECTUS select ARD‑SELECT‑BP Installation Manual

Bosch LECTUS select ARD‑SELECT‑BP Installation Manual

Advertisement

LECTUS select
ARD‑SELECT‑BP | ARD‑SELECT‑BPK | ARD‑SELECT‑BO |
ARD‑SELECT‑BOK | ARD‑SELECT‑WP | ARD‑SELECT‑WPK |
ARD‑SELECT‑WO | ARD‑SELECT‑WOK | ARA‑SELECT‑WWA |
ARA‑SELECT‑SWA
en
Installation manual
1
2
3
6
4
5
9
8
7
E
0
C

Advertisement

Table of Contents
loading

Summary of Contents for Bosch LECTUS select ARD‑SELECT‑BP

  • Page 1 LECTUS select ARD‑SELECT‑BP | ARD‑SELECT‑BPK | ARD‑SELECT‑BO | ARD‑SELECT‑BOK | ARD‑SELECT‑WP | ARD‑SELECT‑WPK | ARD‑SELECT‑WO | ARD‑SELECT‑WOK | ARA‑SELECT‑WWA | ARA‑SELECT‑SWA Installation manual...
  • Page 3: Table Of Contents

    Assembling the reader module 2.5.1 Configuring the reader (DIP switches) 2.5.2 Connecting and mounting the reader module 2.5.3 Unmounting the reader module 2.5.4 Resetting OSDP-key Care instructions Technical specifications More information Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 4: General

    Introduction This installation manual is aimed at authorized service providers. The installation manual contains instructions on the installation and configuration of the Bosch Security Systems proximity reader LECTUS select. Figure 1.1: LECTUS select readers 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V.
  • Page 5: Safety

    Installation and assembly of electrical components must be carried out by a qualified electrician. Caution! The circuit board is at risk from electrostatic discharge. Appropriate precautionary measures (grounding, etc.) must be observed. Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 6: Disposal

    Dispose such equipment according to local laws and regulations, to allow their reuse and/or recycling. This will help in conserving resources, and in protecting human health and the environment. 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 7: Components

    LECTUS select General | en Components Quantity Component Reader module Locking bar Screws Quick installation guide Safety instructions Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 8: Functional Requirements

    They are suitable for both indoor and outdoor use. Connection type: 8-pin screw / plug-in terminal Figure 1.2: LECTUS select readers without and with keypad 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 9 16 mm Wall bracket for flush mounting (part included) The wall bracket is included in the reader delivery. 7 mm 71.6 mm 56 mm 14.5 mm 50.5 mm 3.5 mm Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 10: Osdp

    Black, OSDP ARD-SELECT-WO White, OSDP ARD-SELECT-BOK Black, OSDP, Keypad ARD-SELECT-WOK White, OSDP, Keypad OSDP protocol is common within the Bosch Access Control Systems product portfolio. 1.5.2 Phg_crypt The following readers support phg_crypt protocol: Commercial Type Number (CTN) Description ARD-SELECT-BP Black, phg_crypt...
  • Page 11: Rfid Technology

    – LEGIC prime / Advant – MIFARE Classic /DESFire / EV 1 The RFID technology that can be used is dependent on the reader configuration and the reader firmware. Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 12: Transponder Data

    Recommendation when using smart card chips for LEGIC "card in card" solutions: A suitability and functional test of the corresponding medium should be carried out before use or if it is planned to be used. 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 13: Reading Distances

    If other transponder media are used (chip type, design, size, production process), the distance ranges may differ and it is recommended to carry out a suitability and functional test of the respective medium before using or planning to use the reader. Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 14 Metal in the "active" effective area of the HF field. The transmission energy is attenuated. This point is particularly relevant when installing the reader components in metal front panels (including metal columns, etc.). 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 15: Installation

    High-energy sources of interference in the range of the modulation and carrier frequencies can also interfere with the transmission. 2.1.1 Mechanical structure of the flush-mount version 2.1.2 Mechanical structure of the surface-mount version Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 16: Installing Data And Supply Lines

    When dimensioning the power supply and the cable cross-sections of the cabling, the maximum current consumption must be taken into account. It is essential to ensure that the input voltage remains constant and corresponds to the technical specifications of the reader. 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 17: Assembly Preparation

    Do not connect DC- (0V) DC+ (from 8V to 30V) Wire diameter Stranded wire AWG 28 - 16 Solid wire AWG 28 - 16 Cable stripping length 6 to 7 mm Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 18: Assembling The Reader

    Use the provided screws to screw the wall bracket onto a DIN device socket with a device screw distance of 60 mm. Support the reader's tear detection by fixing the perforated tear-off tab with an additional locking screw. 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 19 Screw the wall-mount frame to the wall using the screws. The connection cable can be inserted from above, below or directly from the wall. Tear detection is supported by fixing the upper left screw. Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 20: Assembling The Reader Module

    To change the reader configuration: Power-off the reader. Set the DIP switches correctly. Power-on the reader. OSDP protocol Address Reserved (default - OFF) Bus terminator resistor (default - OFF) 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 21: Connecting And Mounting The Reader Module

    After it has successfully clicked into place, slide the locking bar into the reader module until it also clicks into place. – NOTE: A clear click can be heard each time it clicks into place. Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 22: Unmounting The Reader Module

    A green LED starts flashing. Disconnect the reader again. – The reader is now back in ‘OSDP installation mode’. – The reader can now be used as a new reader. 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 23: Care Instructions

    Do not use cleaning agents with mechanical effects such as scouring milk, scouring sponge, etc. Only clean the reader with a soft, damp cloth and only use clear water. Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 24: Technical Specifications

    Third-party software Reading technology LEGIC prime* LEGIC advant MIFARE Classic* MIFARE DESFire EV1 & EV2 ISO14443A (CSN / UID)* ISO15693 (CSN / UID)* require specific configuration with OSDP protocol 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 25 LECTUS select Technical specifications | en Connectivity Reader interfaces RS485 Protocol OSDP phg_crypt Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 26: More Information

    | More information LECTUS select More information Visit the Bosch online product catalog for the latest technical documentation for this product. Manufacturing dates For product manufacturing dates, go to www.boschsecurity.com/datecodes/ and refer to the serial number on the product label.
  • Page 27 LECTUS select More information | Bosch Security Systems B.V. 2021-02 | 01 | F.01U.389.837 Installation manual...
  • Page 28 | More information LECTUS select 2021-02 | 01 | F.01U.389.837 Bosch Security Systems B.V. Installation manual...
  • Page 30 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2021 202103121242...

Table of Contents