Page 1
Pistol grip with 1D CCD, 1D Laser, or 1D/2D CCD image scanner (x1) Stylus (x 1) Battery pack for pistol grip (x 1) Views of PG-200E/201E Front View Left Side View 1D CCD or 1D Laser or 1D/2D CCD...
Page 2
FCC NOTES This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Connecting PG-200E/201E onto MT-series Tablet PG-200E/201E is designed for users to easily operate the scanner and normally provided with a three different types of scan engine, including 1D CCD, 1D Laser, and 1D/2D CCD scan engines. To install the pistol grip onto the tablet, refer to the MT-series user manual.
Page 4
Code Options for 1D CCD Scanner Please be noted that the steps required to efficiently configure 1D CCD scanner are offered as follows. Scan SET label Scan required option Scan END label USB-HID interface To successfully change your current interface type to USB-HID, make sure you scan the sequence of programming labels in the order as follows: SET label >XZ label>SU label>XZ label Factory mode...
Page 6
Without keyboard Keyboard language German French Dutch Japanese...
Page 7
Special Options Do not use numpad Use numpad Auto numlock mode No CAPSLOCK mode CAPSLOCK mode Auto CAPSLOCK mode Intercharacter delay for wedges/USB...
Page 9
Enable Code 39 Enable Codabar Enable Interleaved 2of5 Enable Chinese Post Matrix 2of5 Enable MSI/Plessey Enable UK/Plessey Enable Code 128 Enable GS1-Databar Setting code specific options...
Page 10
UPC-A, No leading zero, transmit CD UPC-A, No leading zero, not transmit CD UPC-A, Leading zero, transmit CD UPC-A, Leading zero, not transmit CD Options for UPC-E UPC-E, No leading digit, transmit CD UPC-E, No leading digit, not transmit CD UPC-E, Leading digit, transmit CD UPC-E, Leading digit, not...
Page 11
Options for EAN-13 and EAN-8 EAN-13 not transmit CD EAN-13 transmit CD EAN-8 not transmit CD EAN-8 transmit CD Disable ISBN translation Enable ISBN translation Case Conversion...
Page 12
No case conversion Convert to upper case Convert to lower case...
Page 13
Code Options for 1D Laser Scanner Trigger Mode There are two options offered to set up Trigger mode: Presentation Mode, which enables the engine automatically to detect barcode, scan and then transmits the data, and Manual Activation Mode, in which the barcode will be decoded after you press down the trigger button.
Page 14
Remove Custom Defaults Activate Defaults To Enable or Disable Symbologies All Symbologies Scan the All Symbologies On code to decode all symbologies. On the other hand, to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology. Codabar...
Page 15
Code 39 Full ASCII *Off Interleaved 2 of 5...
Page 18
UPC-A Convert UPC-A to EAN-13 * Transmit UPC-A to UPC-A Transmit UPC-A to EAN-13 UPC-A Addenda 2 Digit Addenda On * 2 Digit Addenda Off...
Page 19
5 Digit Addenda On 5 Digit Addenda Off UPC-A Addenda Required When Required is scanned, the engine will only read UPC-A bar codes that have addenda. You must then turn on a 2 or 5 digit addenda. Required *Not Required UPC-E0 Most U.P.C.
Page 23
Code Options for 1D/2D CCD Scanner Trigger Mode For 2D scanner, two trigger modes are offered: Auto Trigger and Manual Trigger. While Auto Trigger Mode is activated, the light source of your scanner will always stay on in order to detect barcode data any time. On the other hand, with enabled Manual Trigger Mode, the barcode label will not be decoded unless the trigger button is pulled.
Page 24
Green aiming detection Red aiming detection No illumination detection User Interface Switch Barcodes with Defaults Setting After the interface type is changed, the current settings will be removed and reset to the default factory settings. Please do remember to restart the scanner to validate the configuration.
Enable Code 128 Enable GS1-Databar Enable GS1-Databar Limited Enable GS1-Databar Expanded Enable QR Code Enable PDF417 Setting code specific options UPC-A, No leading zero, transmit CD UPC-A, No leading zero, not transmit CD UPC-A, Leading zero, transmit CD UPC-A, Leading zero, not transmit CD...
Options for UPC-E UPC-E, No leading digit, transmit CD UPC-E, No leading digit, not transmit CD UPC-E, Leading digit, transmit CD UPC-E, Leading digit, not transmit CD Options for EAN-13 and EAN-8 EAN-13 not transmit CD EAN-13 transmit CD EAN-8 not transmit CD EAN-8 transmit CD Disable ISBN translation Enable ISBN translation...
Page 28
Case conversion No case conversion Convert to upper case Convert to lower case Floodlight and aiming options Disable floodlight Enable floodlight Alternating floodlight Keyboard wedge/USB options With keyboard Without keyboard Keyboard language German...
Need help?
Do you have a question about the PG-200E and is the answer not in the manual?
Questions and answers