NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
Belt drive 14 industrial air curtain submittal package (25 pages)
Summary of Contents for Mars LVP2 2 Series
Page 1
Company Seal or Stamp (Electronic Signature Preferred) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Page 2
CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Page 3
NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Page 4
25-36” Units = 49 dBA, 42” Unit = 50 dBA, 48” Unit = 52 dBA, 60-96” Units = 53 dBA, 108-144” Unit = 54 dBA NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Page 6
LPV2/LPN2 115V Unheated Wiring diagram with Door switch LPV2 Wiring LPN2 Wiring Main power from circuit breaker at 115v 1MTR 1MTR...
Page 7
LPV2/LPN2 208/230V Unheated Wiring diagram with Door switch LPV2 Wiring LPN2 Wiring Main power from circuit breaker at 208/230v 1MTR 1MTR...
Page 8
3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
Page 9
Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
Page 10
Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. OVERVIEW GENERAL SAFETY INFORMATION Mars Air Curtains are Use this product only in designed cover the manner intended door openings, by the manufacturer.
Page 11
Verify that all parts, components and accessories, and the correct quantities of each have been received. If any FIG. 1 items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
Page 12
NOTE 6. Use four (4) threaded rods for overhead installation or For accessory installation, reference Accessory four (4) threaded bolts for wall installation. All hardware Installation Supplement. is field provided by others. (FIG. 3) For heated products, reference Heated Products Supplement.
Page 13
(6) months. DISCLAIMER To clean the product, perform the following: Mars reserves the right to change specifications and product design without notice. Such revisions do not 1. Verify the product has been disconnected from the entitle...
Page 14
TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
Page 15
TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)
Page 16
Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
Page 17
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
Page 18
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications.
Page 19
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC LEED Submittals: Provide documentation of how the requirements of Credit will be met: List of proposed materials with recycled content. Indicate post-consumer recycled content and pre-consumer recycled content for each product having recycled content.
Page 20
PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
Page 21
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC Unheated: 8-7/8 inches deep by 8 inches high (including discharge nozzle) by width of unit. Electric Heated: 11-3/4 inches deep by 8 inches high (including discharge nozzle) by width of unit.
Page 22
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC LPV272-1: 72 Inch (1830 mm) Wide Units: 1800 feet/min (9.1 m/s) single 1/6HP motor/fan assembly. LPV284-2: 86 Inch (2184 mm) Wide Units: 1800 feet/min (9.1 m/s) two 1/6HP motor/fan assembly.
Page 23
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC LPN2108-2: 110 Inch (2794 mm) Wide Units: 1800 feet/min (9.1 m/s) two 1/6HP motor/fan assembly. LPN2120-2: 122 Inch (3099 mm) Wide Units: 1800 feet/min (9.1 m/s) two 1/6HP motor/fan assembly.
Page 24
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC Thermostat: Wall-mounted 208-Volt operation, with heater on/off selection. Thermostat: Wall-mounted 230-Volt operation, with heater on/off selection. Thermostat: Wall-mounted optional 24-Volt operation, with heater on/off selection. Hot Water Heaters: Provide finned tube water coils for field mounting on air intake side of the air curtain cabinet with opposite end connections.
Page 25
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC Optional remote mounted high resolution 7” Color LCD Display with resistive touchscreen technology Fully programmable controller Connect and control via any web browser Factory built wireless router with over 50 feet range Pre-set and fully customizable programs Time delay (Passive &...
Page 26
Mars Low Profile Series 2-CSI-Spec Revised 4/26/2023 MARS AIR SYSTEMS, LLC Install joint sealants as specified in Section 07 92 00. Coordinate with electrical power as specified in Section 26 05 00. Install door limit switches and adjust for correct operation.
Page 27
LPV2 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Need help?
Do you have a question about the LVP2 2 Series and is the answer not in the manual?
Questions and answers