NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for
previously purchased equipment.
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
Hot water/steam heated industrial air curtain (28 pages)
Summary of Contents for Mars QuietPro QP836-1E AL Series
Page 1
þÿ (Electronic Signature Preferred) NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Page 2
CSI Spec Reference Links NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
Page 3
• The AMCA Certified Ratings Seal applies to airflow rate, average outlet velocity, outlet velocity uniformity, velocity projection, and power rating at free delivery only. NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Page 4
NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Page 7
Single Pole, R.G.W. 99-182 - Cover, Lockable, Clear NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Page 8
3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
Page 9
Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
Page 10
Warning: To reduce the risk of fire, electric shock, or injury to persons, do not use replacement parts that have not been recommended by the manufacturer. OVERVIEW GENERAL SAFETY INFORMATION Mars Air Curtains are designed cover Use this product only in door openings,...
Department. If damaged upon arrival, file a claim wall mounted plate must be on the bottom. immediately with the carrier. Any physical damage to the unit after acceptance is not the responsibility of Mars Air Systems. UNPACKING Verify that all parts, components and accessories, and the correct quantities of each have been received.
Page 12
8. Optional Adjustable Mounting Brackets, Side Extension NOTE Plates, and Extended Wall Mounted Brackets are For accessory installation, reference Accessory available for installations over a Vertical Lift or Drum Installation Supplement. Roll-up type door (reference Accessory Installation Supplement). For heated products, reference Heated Products 9.
On average, under normal usage conditions, the product should require a thorough cleaning once every DISCLAIMER six (6) months. Mars reserves the right to change specifications and To clean the product, perform the following: product design without notice. Such revisions do not entitle...
Page 14
Document No: HT-IOM Date: 10/20/2023 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the unit’s specific IOM Manual for safety, installation, and startup information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
Page 15
Hot Water and Steam Heated Products Hot water and steam heated products are certified only for indoor use. Low Profile 2, Standard 2, High Velocity 2, Extra Power 2, and Phantom series units are shipped with coils mounted in the interior of the unit. Wind Stopping and WindGuard units are shipped with coils factory mounted to the exterior of the unit.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)
Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
Page 19
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
Page 20
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications.
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC LEED Submittals: Provide documentation of how the requirements of Credit will be met: List of proposed materials with recycled content. Indicate post-consumer recycled content and pre-consumer recycled content for each product having recycled content.
Page 22
PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
Page 23
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC Electric Heated: 13 inches deep by 8-5/8 inches high (including discharge nozzle) by width of unit. Hot Water/Steam Heated: Depth 13 inches deep by 8-5/8 inches high (including discharge nozzle) by width of unit plus 10 inches for...
Page 24
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC QP896-2: 98 Inch (2489 mm) Wide Units: 1800 feet/min (9.1 m/s) two 1/6HP motor/fan assembly. QP8108-2: 110 Inch (2794 mm) Wide Units: 1800 feet/min (9.1 m/s) two 1/6HP motor/fan assembly.
Page 25
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC Thermostat: Wall-mounted optional 24-Volt operation, with heater on/off selection. Hot Water Heaters: Provide finned tube water coils for field mounting on air intake side of the air curtain cabinet with opposite end connections.
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC Connect and control via any web browser Factory built wireless router with over 50 feet range Pre-set and fully customizable programs Time delay (Passive & Adaptive) Factory Integrated temperature control sensors. No external thermostat required.
Page 27
Mars Quiet Pro 8-CSI-Spec Revised 8/20/2024 MARS AIR SYSTEMS, LLC Coordinate with electrical power as specified in Section 26 05 00. Install door limit switches and adjust for correct operation. Provide connection to piped services and utilities as specified in Section 22 10 00 and 23 21 00.
Page 28
QP8 Series CSI spec (Word doc) NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Need help?
Do you have a question about the QuietPro QP836-1E AL Series and is the answer not in the manual?
Questions and answers