Omron XE Datasheet page 3

Enclosed switches
Table of Contents

Advertisement

■ Ratings
Contact
Contact
ZE-@
ZV-@
ZV2-@
XE-@
XV-@
XV2-@
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Inrush current
NC
NO
■ Characteristics
Degree of protection
Durability (see note 3)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Dielectric strength
Vibration resistance
Shock resistance (see note 4)
Ambient temperature (see note 1)
Ambient humidity
Weight
Note: 1. The above figures are initial values.
2. IP65 for @E-N models and IP60 for @E-Q models.
3. The values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
4. At the operation limit positions.
5. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
6. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.
Rated voltage
Resistive load
NC
125 VAC
15 A
250 VAC
15 A
480 VAC
10 A
125 VDC
0.5 A
250 VDC
0.25 A
8 VDC
15 A
14 VDC
15 A
30 VDC
15 A
125 VDC
10 A
250 VDC
3 A
30 A max.
15 A max.
IP65 (see note 2)
Mechanical:
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Electrical:
Z@: 500,000 operations min., for 15 A, 250 VAC resistive load
X@: 100,000 operations min., for 10 A, 125 VDC resistive load
Plunger type: 0.01 mm to 0.5 m/s
Lever type:
0.02 mm to 0.5 m/s
Mechanical: 120 operations/min
Electrical:
20 operations/min
50/60 Hz
100 M min. (at 500 VDC)
15 m max. (initial value)
50 max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each
terminal and non-current-carrying metal part (1,500 VAC for Z@ models and X@ models)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 4)
Destruction: 1,000 m/s
2
Malfunction: 100 m/s
Operating: –10 C to 80 C (with no icing)
Operating: General-purpose type: 85% max.
Sealed type:
Approx. 260 to 280 g
Non-inductive load
Lamp load
NO
NC
NO
3 A
1.5 A
2.5 A
1.25 A
1.5 A
0.75 A
0.5 A
0.25 A
3 A
3 A
3 A
3 A
3 A
3 A
3 A
1.5 A
1.5 A
0.75 A
2
min.
2
min. (see note 5), 50 m/s
min. (see note 6)
95% max.
Enclosed Switches
Inductive load
Inductive load
Motor load
NC
NO
NC
15 A
5 A
15 A
3 A
6 A
1.5 A
0.05 A
0.05 A
0.03 A
0.03 A
15 A
15 A
10 A
15 A
10 A
10 A
10 A
10 A
10 A
7.5 A
6 A
6 A
2 A
1.5 A
2 A
ZE/ZV/XE/XV
NO
2.5 A
1.5 A
0.75 A
10 A
10 A
6 A
4 A
1 A
F-121