Omron X Datasheet
Omron X Datasheet

Omron X Datasheet

General-purpose basic switch

Advertisement

General-purpose Basic Switch
X
Direct Current Switch with Built-in Magnetic
Blowout
• Incorporates a small permanent magnet in the contact mecha-
nism to deflect the arc to effectively extinguish it.
• Same shape and mounting procedures as the Z Basic Switch-
es.
Model Number Structure
■ Model Number Legend
X-10G@-@
1 2 3
4
1. Ratings
10:
10 A (125 VDC)
2. Contact Gap
G:
0.9 mm
3. Actuator
None: Pin plunger
D:
Short spring plunger
S:
Slim spring plunger
Q:
Panel mount plunger
Q21: Panel mount cross roller plunger
Q22: Panel mount roller plunger
L:
Leaf spring
W:
Hinge lever
W2:
Hinge roller lever
W21: Short hinge lever
W22: Short hinge roller lever
W4:
Low-force hinge lever
M:
Reverse hinge lever
M2:
Reverse hinge roller lever
M22: Reverse short hinge roller lever
4. Terminals
None: Solder terminal
B:
Screw terminal (with toothed washer)
General-purpose Basic Switch
X
F-149

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Omron X

  • Page 1 Direct Current Switch with Built-in Magnetic Blowout • Incorporates a small permanent magnet in the contact mecha- nism to deflect the arc to effectively extinguish it. • Same shape and mounting procedures as the Z Basic Switch- Model Number Structure ■ Model Number Legend X-10G@-@ 1 2 3 1.
  • Page 2: Ordering Information

    X-10GM2-B Reverse hinge X-10GW21 X-10GW21-B roller lever Short hinge lever Note: The plungers of reverse-type models are continuously pressed by the compression coil springs and the plungers are freed by operating the levers. Specifications ■ Approved Standards Agency Standard File No.
  • Page 3 Note: 1. The above values are for the steady-state current. 2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current.
  • Page 4: Engineering Data

    2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. ■ Dimensions and Operating Characteristics The models, illustrations, and graphics are for screw-terminal models. (The dimensions for models that are omitted here are the same as for pin- plunger models.) OF max.
  • Page 5 16 dia. 16.3 (see note 2) Note: 1. Stainless-steel pin plunger 2. Three vent holes 3. Imperfect screw part with a maximum length of 1.5 mm. OF max. 5.00 N {510 gf} Panel Mount Roller Plunger RF min. 1.12 N {114 gf} X-10GQ22-B 23.3 0.25...
  • Page 6 2.45 N {250 gf} Short Hinge Lever RF min. 0.31 N {32 gf} 26.2 (see note 2) X-10GW21-B t = 1 (see note 1) t = 1 (see note 1) OT min. 2.1 mm 28.2 R MD max. 1.7 mm OP FP 20.2...
  • Page 7 0.78 to 1.18 N m {8 to 12 kgf cm}. Note: 1. Tighten the terminal screws to a torque of 0.78 to 1.18 N·m {8 to 12 kgf·cm}. 2. In case of DC voltage, set the COM to the positive terminal.
  • Page 8: Mounting Holes

    If the current becomes 0.6 to Switch when the Switch is side-mounted on the panel. 1.2 A or of the time constant L/R exceeds 7 ms, be sure to provide an Too fast operating speed and too long overtravel of the roller plunger arc suppressor.

This manual is also suitable for:

X-10gX-10g-bX-10gsX-10gs-bX-10gdX-10gd-b ... Show all