■ Ratings
Rated voltage
Resistive load
8 VDC
10 A
14 VDC
10 A
30 VDC
10 A
125 VDC
10 A
250 VDC
3 A
Note: 1. The above values are for the steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above electrical ratings also apply to the AC voltage.
6. With the reverse-type models (X-10GM@), the normally closed circuits and normally open circuits are reversed.
7. The ratings values apply under the following test conditions:
Ambient temperature: 20 2 C
Ambient humidity: 65 5%
Operating frequency: 20 operations/min
■ Characteristics
Operating speed
Operating frequency
Insulation resistance
Contact resistance
Dielectric strength
Vibration resistance
Shock resistance
Durability
Degree of protection
Degree of protection against
electric shock
Proof tracking index (PTI)
Switch category
Ambient temperature
Ambient humidity
Weight
Note: 1. The values are for the pin plunger models. (Contact your OMRON representative for other models.)
2. Malfunction: 1 ms max.
■ Contact Specification
Item
Contacts
Material
Gap (standard value)
Inrush current
NC
NO
Non-inductive load
Lamp load
NC
3 A
3 A
3 A
3 A
1.5 A
0.1 mm to 1 m/s (see note 1)
Mechanical: 240 operations/min
Electrical:
20 operations/min
100 M min. (at 500 VDC)
15 m max. (initial value)
1,500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between current-carrying metal parts and
the ground, and between each terminal and non-current-carrying metal parts
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 2)
2
Destruction: 1,000 m/s
{approx. 100G} max.
2
Malfunction: 300 m/s
{approx. 30G} max. (see note 1, 2)
Mechanical: 1,000,000 operations min.
Electrical:
100,000 operations min.
IP00
Class I
175
D (IEC335-1)
Operating: 25 C to 80 C (with no icing)
Operating: 35% to 85% max.
Approx. 27 to 63 g
X-10
Silver alloy
0.9 mm
30 A max.
15 A max.
Inductive load
NO
NC
1.5 A
10 A
10 A
1.5 A
10 A
10 A
1.5 A
10 A
10 A
1.5 A
7.5 A
6 A
0.75 A
2 A
1.5 A
■ Contact Form (SPDT)
COM
NC
NC
Note: With the reverse-type models (X-10GM@), the NC and NO ter-
minal arrangements are reversed.
General-purpose Basic Switch
Inductive load
Motor load
NO
NC
NO
5 A
2.5 A
5 A
2.5 A
5 A
2.5 A
5 A
2.5 A
2 A
1.5 A
X