If the set value is 7, 8, or 9, the carrier frequency will be multiplied by
the same factor as the output frequency.
n080=7
2.5 kHz
fc=12 fout
1.0 kHz
n080=8
2.5 kHz
fc=24 fout
1.0 kHz
n080=9
2.5 kHz
fc=36 fout
1.0 kHz
fc=Carrier Frequency
83.3 Hz
208.3 Hz
fc=Carrier Frequency
41.6 Hz
104.1 Hz
fc=Carrier Frequency
27.7 Hz
69.4 Hz
6 Programming Features
fout=Output Frequency
fout=Output Frequency
fout=Output Frequency