■ Characteristics
Degree of protections (see note 3)
Durability (see note 4)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (U
i
Switching overvoltage
Pollution degree
(operating environment)
Short-circuit protective device
(SCPD)
Conditional short-circuit current
Conventional enclosed thermal cur-
rent (I
)
the
Protection against electric shock
OFF reverse voltage
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight (see note 5)
Note: 1. The above figures are for standard currents.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3. The head section of the plunger type SHL-D(Q)@@ is excluded.
4. Durability values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
5. The values are for the plunger-type models.
■ Operating Characteristics
Model
SHL-D55
SHL-D55-01
OF max.
9.81 N
RF min.
1.96 N
PT max.
1.5 mm
OT min.
2 mm
MD max.
0.5 mm
OP
34 0.8 mm
FP max.
---
Model
SHL-W155
SHL-W155-01
OF max.
2.35 N
RF min.
0.44 N
PT max.
13 mm
OT min.
5 mm
MD max.
4 mm
OP
21.5 1 mm
FP max.
34.5 mm
F-48
Enclosed Switch
IP67 (EN60947-5-1)
Mechanical: 10,000,000 operations min.
Electrical:
500,000 operations min.
0.1 mm to 0.5 m/s (hinge lever models)
Mechanical: 120 operations/min
Electrical:
30 operations/min
50/60 Hz
100 M
min. (at 500 VDC)
15 m
max.(initial value)
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal part and
ground, and between each terminal and non-current-carrying metal part
)
150 V (EN60947-5-1)
1,000 VAC max., 300 VDC max. (EN60947-5-1)
3 (EN60947-5-1)
10 A fuse type gG (IEC269)
100 A (EN60947-5-1)
5 A (EN60947-5-1)
Class II (grounding not required with double insulation)
1,000 VAC max., 300 VDC max. (EN60947-5-1)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating:
–10 C to 80 C (no icing)
Operating:
95% max.
Approx. 62 to 72 g
SHL-Q55
SHL-Q55-01
9.81 N
1.96 N
1.5 mm
2 mm
0.5 mm
34 0.8 mm
---
SHL-W255
SHL-W255-01
3.92 N
0.78 N
8 mm
3 mm
2.5 mm
33 1 mm
41 mm
SHL
2
min.
2
min.
SHL-Q2255
SHL-Q2255-01
9.81 N
1.96 N
1.5 mm
2 mm
0.5 mm
43 0.8 mm
---
SHL-W2155
SHL-W2155-01
2.55 N
0.49 N
13 mm
5.5 mm
4 mm
33.5 1 mm
46.5 mm
SHL-Q2155
SHL-Q2155-01
9.81 N
3.14 N
1.96 N
0.78 N
1.5 mm
8 mm
2 mm
3 mm
0.5 mm
2.5 mm
43 0.8 mm
21.5 1 mm
---
29.5 mm
SHL-W355
SHL-W355-01
3.92 N
2.55 N
0.78 N
0.49 N
8 mm
13 mm
3 mm
5.5 mm
2.5 mm
4 mm
44.5 1 mm
44.5 1 mm
52.5 mm
57.5 mm
SHL-W55
SHL-W55-01
SHL-W3155
SHL-W3155-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shl series

Table of Contents