Fixed Displays

2-4-2 Text (Fixed Display)

Function Outline
Reference: When the PT is in NT20S or NT30/620 compatible mode, images can be in-
Restrictions
98
The timing of the flashing is the same for all elements.
Both text (page 98) and mark (page 103) fixed displays will overlap each other in
accordance with the order in which they were created. However, the way in
which they overlap can be changed with the Support Tool.
These are character strings that are continually displayed as a fixed display.
Standard, flash, and inverse flash displays are possible (inverse display can be
specified by exchanging the foreground color and background color of the char-
acter string).
Since the order of display will always follow the order in which the elements are
created with the Support Tool (character strings created later will overlay others
created earlier), the order of creation must be considered when character
strings are going to overlap.
Alphanumerics and symbols can be displayed.
cluded within character strings of fixed displays. Refer to Appendix C for details
on the NT20S and NT30/620 compatible modes (page 451).
Up to 65,535 of the following graphics can be registered on one screen. For
overlapping screens comprising 8 child screens, the maximum is 524,280
(65,535 8 screens).
Fixed display text, circles, arcs, sectors, polylines, polygons, rectangles, til-
ing, marks
There is no restriction on the number of graphics that can be registered for one
screen data file: any number can be registered as long as the data file capacity is
not exceeded.
The following numbers of character can be displayed in one text display ele-
ment, depending on the scale.
Magnification
1 1 (Equal)
Up to 32 characters
1 2 (High)
Up to 32 characters
2 1 (Wide)
Up to 16 characters
2 2
Up to 16 characters
3 3
Up to 10 characters
4 4
Up to 8 characters
8 8
Up to 4 characters
If the text size exceeds the screen size, the Support Tool changes its display
position automatically so that the text is displayed within the screen. In case
the text can not be displayed within the screen even if the Support Tool has
changed its position, the error message will be displayed. In this case, change
the number of characters or scale size.
NT31C
NT21
NT31/NT31C
Up to 40 characters
Up to 40 characters
Up to 20 characters
Up to 20 characters
Up to 13 characters
Up to 10 characters
Up to 5 characters
Section
2-4
NT631/NT631C
Up to 80 characters
Up to 80 characters
Up to 40 characters
Up to 40 characters
Up to 26 characters
Up to 20 characters
Up to 10 characters

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt631Nt31 seriesNt21 seriesNt631 series

Table of Contents