G9SX
Expansion unit
Item
Rated load
Rated carry current
Maximum switching voltage
Characteristics
Item
Operating time (OFF to ON state)
Response time (ON to OFF state)
Durability Electrical
Mechanical
Ambient temperature
Connections

Internal Connection

G9SX-AD322-@ (Advanced Unit)
A1
T11
T12 T21 T22 T31 T32 T33 Y1
(See
note 1.)
Safety
Safety
Reset/Feedback
Power
Input 1
Input 2
supply
circuit
Safety output control
A2
S14
S24 S34 S44 S54 L1 X1 X2
(See note 3.)
Note: 1. Internal power supply circuit is not isolated.
2. Logical AND input is isolated.
3. Outputs S14 to S54 are internally redundant.
G9SX-BC202-@ (Basic Unit)
A1
T11
T12 T21 T22 T31 T32 T33 Y1
(See
note 1.)
Safety
Safety
Reset/Feedback
Power
Input 1
Input 2
supply
circuit
Safety outputs control
A2
S14
S24
L1 L2
(See note 2.)
Note: 1. Internal power supply circuit is not isolated.
2. Outputs S14 to S24 are internally redundant.
G9SX
2
G9SX-EX-@
250 VAC, 3A / 30 VDC, 3A
(resistive load)
3 A
250 VAC, 125 VDC
G9SX-AD322-@
G9SX-ADA222-@
50 ms max. (Safety input: ON)
100 ms max.
(Logical AND connection input: ON)
15 ms max.
---
---
-10 °C +55 °C (with no icing or condensation)
T41 T42
(See note 2.)
Cross
fault
Logical AND input
detection
Input
input
Expansion Unit
Auxiliary
output control
output control
Cross
fault
Input
detection
input
Auxiliary
output control
X1 X2
Safety network and units
G9SX-BC202-@
50 ms max. (Safety input: ON)
G9SX-EX401-@/G9SX-EX041-T-@ (Expansion
Unit / Expansion Unit OFF-delayed model)
A1
(See
note 1.)
Safety
output
Power
control
supply
K1
circuit Auxiliary
Exp.
output
sig.
control
IN
A2
X2
Note: 1. Internal power supply circuit is not isolated.
2. Relay outputs are isolated.
G9SX-ADA222-@ (Advanced Unit)
T12 T21 T22 T31 T32 T33 Y1 T41 T42 T51 T52
A1
T11
(See
note 1.)
Safety
Safety
Reset/Feedback
Power
Input 1
Input 2
supply
circuit
Safety output control
A2
S14
S24 S44 S54 L1 L2 X1 X2
(See note 3.)
Note: 1. Internal power supply circuit is not isolated.
2. Logical AND input are isolated.
3. Outputs S14 to S54 are internally redundant.
G9SX-EX-@
30 ms max.
10 ms max.
100,000 cycles min.
5,000,000 cycles min.
13 23 33 43
(See note 2.)
Exp.
sig.
K2
OUT
14 24 34 44
(See
note
2.)
Cross
Logical
Logical
fault
detection
AND input
AND input 2
Input
input
Auxiliary
Expansion Unit
output control
output control
7