G9SX FLEXIBLE SAFETY UNIT
T h e l o g i c a l a l t e r n a t i v e i n s a f e t y c o n t r o l
F l e x i b i l i t y i n a p p l i c a t i o n
»
C l e a r d i a g n o s i s
»
E a s y m a i n t e n a n c e
»
Advanced Industrial Automation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G9SX and is the answer not in the manual?

Questions and answers

Summary of Contents for Omron G9SX

  • Page 1 G9SX FLEXIBLE SAFETY UNIT T h e l o g i c a l a l t e r n a t i v e i n s a f e t y c o n t r o l F l e x i b i l i t y i n a p p l i c a t i o n »...
  • Page 2 Modular - It allows the machine safety function to be split into separate function blocks for easy diagnosis and maintenance. system. Using microprocessor technology, the...
  • Page 3 Advanced units G9SX-AD and G9SX-ADA • 1 two-channel safety input • Up to 3 solid state safety outputs (instantaneous) and 2 solid state safety outputs (OFF-delayed up to 15 sec or 150 sec) • 1 logical “AND” input for G9SX-AD G9SX-EX-T •...
  • Page 4 AND connection. Depending on In a machining center, for example, when the Emergency Stop the safety system, up to five tiers can be set up for individual Switch is pressed, the entire machine will stop. When a door stop of machine parts.
  • Page 5 Unlike conventional relays, the safety outputs of the G9SX-BC highlight the system status (output and error) to your control and G9SX-AD are solid state, so there are no mechanical parts system to provide full transparency and displays where the to wear out. This design is very effective for frequent fault area occurs.
  • Page 6: Ordering Information

    0 to 150 s in Screw terminals G9SX-AD322-T150-RT 16 steps Cage clamp terminals G9SX-AD322-T150-RC The OFF-delay time can be set in 16 steps as follows: T15: 0/0.2/0.3/0.4/0.5/0.6/0.7/1/1.5/2/3/4/5/7/10/15 s, T150: 0/10/20/30/40/50/60/70/80/90/100/110/120/130/ 140/150 Advanced unit 2 logical AND inputs Safety outputs Auxiliary outputs No. of input Max.
  • Page 7 2. Relay outputs are isolated. 3. Outputs S14 to S54 are internally redundant. G9SX-BC202-@ (Basic Unit) G9SX-ADA222-@ (Advanced Unit) T12 T21 T22 T31 T32 T33 Y1 T41 T42 T51 T52 T12 T21 T22 T31 T32 T33 Y1 (See (See note note 1.)
  • Page 8 OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.omron-industrial.com Austria France Netherlands Spain Tel: +43 (0) 1 80 19 00 Tel: +33 (0) 1 56 63 70 00...