Installation Site
Install the product in a place that meets the following conditions:
• Surrounding temperature of 0 to +50 °C
• No rapid changes in temperature (place where dew does not form)
• Relative humidity of between 35 to 85 %
• No presence of corrosive or flammable gases
• Place free of dust, salts and iron particles
• Place free of vibration and shock
• Place out of direct sunlight
• Place where it will not come into contact with water, oils or chemicals
Orientation of Product
To improve heat dissipation, install the product in the
following orientation only.
Ambient Temperature
• Maintain a minimum clearance of 50 mm above and below the
controller to improve air circulation. A minimum clearance of
10 mm between other devices must also be maintained on the
right and left sides of the product. However, if the adjacent
devices do not generate heat, provide at least 50 mm of
clearance from the top of the Controller. For the clearance at
the bottom and sides, follow the mounting method.
• Do not install the product immediately above significant
heat sources, such as heaters, transformers, or
large-capacity resistors.
• Do not let the ambient temperature exceed 50 °C (122 °F).
• Provide a forced-air fan cooling or air conditioning if the
ambient temperature is near 50 °C (122 °F) so that the
ambient temperature never exceeds 50 °C (122 °F).
Noise Resistance
• Do not install the product in a cabinet containing
high-voltage equipment.
• Do not install the product within 200 mm of power cables.
Component Installation and Handling
• OMRON Components
Use only the camera and cables designed specifically for the product.
Failure to observe this may result in malfunction or damage of the product.
• Connecting/Disconnecting Camera and Cables
Always turn OFF the Controller's power before connecting or disconnecting a camera
or cable.
• Touching Signal Lines
To prevent damage from static electricity, use a wrist strap or another device for
preventing electrostatic discharges when touching terminals or signal lines in
connectors.
• Handling a USB Memory
To remove a USB memory, make sure that data is not being read or written to it.
The LED on the USB memory flashes while data is being read or written, so make sure that it is lit steadily before removing the
memory.
• Turning OFF the Power
Do not turn OFF the power while a message is being displayed indicating that processing is being performed. Data in memory will
be corrupted, and the product may not operate correctly the next time it is started.
• Using the RESET Signal
Do not use the RESET input immediately after power is turned ON. When using the RESET input to synchronize startup timing,
wait at least 15 second after the Controller's power supply is turned ON before turning ON the RESET signal.
Maintenance
Turn OFF the power and take safety precautions before conducting inspections. Electrical shock can result from attempting safety
inspections with the power turned ON.
• Clean the lens with a lens-cleaning cloth or air brush.
• Lightly wipe off dirt with a soft cloth.
• Dirt on the CCD must be removed using an air brush.
• Do not use thinners or benzene.

Confirming Package Contents

• Controller
• Instruction Manual (this manual)
• Booklet ("Please Read First")
• Mounting bracket (for panel)
• Touch pen
3

Precautions for Correct Use

LCD integrated type
Box type
Qty.: 1
Qty.: 1
Qty.: 1
Qty.: 6
Qty.: 1
Do not install in this orientation.
Do not install in this orientation.
* Supplied with the LCD integrated type only.
* Supplied with the LCD integrated type only
(provided inside the controller).
To reserve ventilation path,
the feet must be mounted
to the side panel that is
positioned at the base.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xpectia fz2-35Xpectia fz2-50Xpectia fz2-55

Table of Contents