4-5-1 Emitter and Receiver Code Switches

Both the emitter and the receiver must be set to the same code. Switch settings other than those given below
will result in a fault condition.
Code #
Emitter Dip Switch
2
A
OFF
B
OFF
C
ON
D
ON

4-5-2 Operating Mode Switches

Operating modes are described on page "Receiver Operating Mode Switch" on page 5. Positions 1 & 2 on SW1
and SW2 in the receiver are used to set the operation mode. Switch settings are given below:
Operating Mode
Automatic Start
Start Interlock
Not Valid
Start/Restart Interlock
8
Emitter
400 mm
(16 in)
Receiver
Floor
Figure 4-1 Installation Example Using Mirrors
Position (SW1)
3
4
OFF
OFF
ON
ON
OFF
ON
ON
OFF
Receiver DIP Switch Position (SW1 & SW2)
Mirrors
900 mm
(36 in)
Receiver Dip Switch Position
(SW1)
3
4
OFF
OFF
ON
OFF
OFF
ON
ON
ON
1
ON
OFF
ON
OFF
4-5 Switch Settings
(SW2)
3
4
OFF
OFF
ON
OFF
OFF
ON
ON
ON
2
ON
ON
OFF
OFF