Omron F3SS Instruction Manual page 14

F3ss series single beam safety sensor
Hide thumbs Also See for F3SS:
Table of Contents

Advertisement

4 Installation
Power Off
Apply Power
Machine MPCE Contacts
Close Machine Start
Machine Run
Interrupt Sensing Beam
Machine MPCE Contacts
Open Machine Stop
Sensing Beam Clear
Indicator On
10
AUTOMATIC START FUNCTIONAL FLOW CHART
F3SS Status
Power Supply "Off"
Power-Up
Sensing Beam Clear
Machine Start
Machine Run Condition
Sensing Beam Blocked
Sensing Beam Blocked
Sensing Beam Clear
Indicator Off
Figure 4-4 Automatic Start Mode Functional Flow chart
Indicators
Run
Interlock
Align
Stop
Green
Yellow
Amber
Red
4-5 Switch Settings
Solid-State
Safety Output
Current Source
Off
On
On
On
Off
Off
On