Correct Usage; Regulations And Standards - Omron F3SH-A Datasheet

Safety light curtain / multi-beam safety sensor
Hide thumbs Also See for F3SH-A:
Table of Contents

Advertisement

Connection
Using a manual reset function and an external
device monitoring function
Emitter
Emitter cable
F39-JC # A-L
S1
S2

Correct Usage

This catalog is intended as a guide for product selection. Be sure to use the instruction manual provided with the product for actual operation.

Regulations and Standards

1. "Type Approval" specified in the Chapter 44. 2 of the Industrial
Safety and Health Law in Japan does not apply to independent
units of the F3SN-A/F3SH-A sensors. This law applies to sys-
tems incorporated with the sensor's.
When using the F3SN-A/F3SH-A sensor in Japan as "safety
devices for presses or shearing machines" as specified in the
Chapter 42 of the same law, apply for approval as a system.
2. (1) The F3SN-A/F3SH-A is electro-sensitive protective equip-
ment (ESPE) in accordance with European Union (EU)
Machinery Directive Annex IV, B, Safety Components, Item 1.
(2) The F3SN-A/F3SH-A complies with the following regulations
and standards:
1. EU Regulations
• Machinery Directive: Directive 98/37/EC
• EMC Directive: Directive 89/336/EEC
2. European standards: EN61496-1 (TYPE 4 ESPE),
prEN61496-2 (TYPE 4 AOPD)
3. International standards: IEC61496-1 (TYPE 4 ESPE),
IEC61496-2 (TYPE 4 AOPD)
4. American standards: UL61496-1 (type 4 ESPE),
UL61496-2 (type 4 AOPD), UL508, UL1998,
CAN/CSA22.2 No. 14, CAN/CSA22.2 No. 0.8
5. JIS standards: JIS B9704-1 (type 4 ESPE),
JIS B9704-2 (type 4 AOPD)
(3) The F3SN-A/F3SH-A received the following approvals from
the EU accredited body DEMKO A/S:
• EC Type-Examination in accordance with the EU Machin-
ery Directive (TYPE 4 ESPE)
• Certificate of a competent body for EMC
• DEMKO Type Approval
Type 4 ESPE (EN61496-1)
Type 4 AOPD (prEN61496-2)
(4) The F3SN-A/F3SH-A received the following approvals from
the Third Party Assessment Body UL:
• Certificate of UL listing for US and Canadian safety standards
Both of which are: TYPE 4 ESPE (UL61496-1),
TYPE 4 AOPD (UL61496-2)
F3SN-A/F3SH-A
Receiver
Receiver cable
F39-JC # A-D
RS-485(A) (gray)
RS-485(B) (pink)
K1
K3
K2
DC24V
When using a auto reset function
S1: External test switch
S2: Interlock/lockout reset switch
S3: Lock-out reset switch (if the switch is not needed,
connect to 24 V DC)
K1, K2: Relays for control of dangerous parts of ma-
chine.
K3: Load, PLC, etc. (for monitor)
Note: If you do not intend to use the external relay mon-
K1
K2
(5) The F3SN-A/F3SH-A received the following approvals from
BG-PRUFZERT of Germany:
• BG test and approval mark
License
Type 4 ESPE (EN61496-1)
Type 4 AOPD (prEN61496-2)
3. The F3SN-A/F3SH-A is designed according to the following stan-
dards. To make sure that the F3SN-A/F3SH-A complies with the
following standards and regulations, you are asked to design and
use it as provided by any other related standards, laws, and regula-
tions. (Underlined regulations are applicable to the F3SN-A only.)
Consult UL or other standardization bodies if you have any ques-
tions.
• EN415-4, prEN691, EN692, prEN693 (European stan-
dards)
• OSHA 29 CFR 1910. 212 (US Industrial Safety and
Health Regulation)
• OSHA 29 CFR 1910. 217 (US Industrial Safety and
Health Regulation)
• ANSI B11. 1 - B11. 19 (US standard)
• ANSI/RIA 15. 06 (US standard)
Emitter
S1
S3
DC24V
itor, connect the auxiliary output that is set for
dark: ON operation to the external relay monitor
input, or use F39-MC11 to disable the external re-
lay monitor function.
G-17

Advertisement

Table of Contents
loading

This manual is also suitable for: