Omron F3SH-A Datasheet page 4

Safety light curtain / multi-beam safety sensor
Hide thumbs Also See for F3SH-A:
Table of Contents

Advertisement

The setting console--the first in the industry--allows you an easy and safe setting of various
functions.
Function display
G-6
Features
Connection indicator
(Power supply indicator)
Channel display
The sensor of series connection
Mode display
Operation switch
UP: Mode select
DOWN: Mode
select, numeric value decrease
R: Mode select, digit move up
L: Mode select, digit move up
CANCEL: Cancel button
ENTER: Confirmation button
Includes two types of blanking functions
Blanking function for changing the detection pattern of the
safety light curtain.
Basic pattern 1: Floating blanking function
This function allows you to disable an unspecified 1, 2, or 3
optical axes. If more than the set optical axes is interrupted,
the output shuts off.
(Example of floating blanking function)
Floating-and-blanking function
Basic pattern 2: Fixed blanking function
Specific optical axes are masked by teaching and disabled.
(Example of fixed blanking function)
Optical axis can be shaded
and disabled when a work
piece is in detection area.
Blanking
Blanking
Fix Blanking Function
The fix blanking function with F3SN,
the instant the work stand removed,
resets blanking, and the invalid
optical axis returns effectively.
Since it is detectable even if a hand
invaded, it is safe.
Blanking release
Other functions to be set with the setting console
● Auxiliary outputs: Outputs such as ON at Dark, ON at Light,
light intensity diagnosis, and lockout can be selected.
● Large indicator lamp outputs: large indicator lamp outputs
can be selected from ON at Dark, ON at Light, light inten-
sity diagnosis, and lockout.
● External device monitoring function: Allows you to monitor
the feedback of external devices.
● Interlock function: Interlocks can be set at power-on and restart.
● Setting copy function: Allows you to copy the settings of one
sensor to another sensor.
● Protect function: Changing of sensor settings can be pro-
hibited and restricted.
Safety Sensors / Components
The moving rod that is
installed on the machine,
can move up and down
in the protective field.
However, nullification of
mere optical axis will
remain as it is, even if
the work piece was removed.
Since it is undetectable even
if a hand invaded, it is dangerous.

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sn-a

Table of Contents