Download Print this page

S&P EMI-TECH Manual page 21

Advertisement

Available languages

Available languages

Heater settings
To change or adjust the control settings when the heater is delivered ex-factory. The following table shows the va-
rious settings.
• Press the CONFIG/PROG key for 5 seconds until the
through the different settings (01 ... 17). Select MODE/OK when the setting (01 ... 17) appears on the screen. With
the +/- keys you can change the setting, and once changed, press MODE/OK again to save it.
• Press CONFIG/PROG again to go back to the main screen.
Temperature unit°C (Celsius) or °F (Fahrenheit).
01
Clock format 24 h or 12 h (am/pm).
02
DST. The heater's clock will automatically adjust to summer/winter time changes.
Activated (YES) / deactivated (NO).
03
The thermostat temperature can be calibrated (Fractions of 0.1°C).
The temperature compensation can be adjusted up to +/- 3ºC
04
ITCS. Smart temperature control system.
Activated (YES) / deactivated (NO).
When the heater is in weekly programme mode (P), the ITCS system connects the heater
in advance, to ensure that the temperature will be at the temperature the user desires at
the exact time that has been set.
This smart process is executed by means of an internal software that takes time measu-
05
rements and means that you DON'T have to set the necessary advance turn-on time for
the heater. Consequently, when the weekly programming is set, the desired temperature
must be indicated with the exact time required, without any advance time setting.
Important: The automatic advance turn-on is set to be maximum 2 h. You must take this
parameter into account if there is a contracted banded price with the electricity supply
company, as the heater may turn on during the high-rate hours.
WIN. "Open windows" detector.
Activated (YES) / deactivated (NO).
This function detects if the room temperature falls by 0.6ºC per minute, over a 4-minute
period. In this case, if the heater is heating, it will automatically switch off for 30 minutes.
The
has been activated.
06
This function will automatically deactivate:
• 30 minutes after activation.
• If the temperature increases +0.2ºC in one minute from the activation point.
• If any key on the heater is pressed.
icon appears fl ashing on the screen. With the +/- keys skip
icon will appear fl ashing on the screen to show that this energy saving function
21

Advertisement

loading
Need help?

Need help?

Do you have a question about the EMI-TECH and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Emi-tech 4Emi-tech 5Emi-tech 6Emi-tech 8Emi-tech 10