Setting the switching points
8-4
Setting the switching points
8-4-1
Teaching the switching points in the normal mode
8-4-2
Setting the sensor
50
The switching points can either be user set (Teach-in mode) with a measured
object positioned at the corresponding distance or can be set using the setting
input, for remote setting.
For each output of the sensor (up to two), up to two switching points can be
user set.
Only one switching point is active in the foreground and background suppres-
sion modes.
For the 2-point window evaluation mode, two switching points must be set.
The sensor is set at the factory for both outputs to BGS, light on.
1. Place the target object in front of the sensor at the desired position.
2. Teach the switching point for output 1:
• Beginning with the
key. Threshold level is obtained and the output/LED is updated. Status
LED is blinking.
• Using the
/
The output/LED is updated immediately.
• Pressing the ENTER
without any activation of the keys, the sensor returns to normal opera-
tion. The status LED is turned off.
3. Teach the switching point for Output 2:
• Beginning with the
key.
The sensor's parameters and the four possible switching points are set as
described in Section 9-1 Setting the sensor using the push buttons or Section
9-2 Setting the sensor with a PC .
key, press it simultaneously with the ENTER
keys an adjustment of the switching point is possible.
key for more than 2 seconds or after 2 minutes
key, press it simultaneously with the ENTER
Section 8-4