Omron CX-PROGRAMMER V9 - REV 12-2009 Operation Manual page 304

Table of Contents

Advertisement

PART 2: CX-Server PLC Tools
CHAPTER 5 – Data Trace/Time Chart Monitor Component
[Trigger
Settings]
[Delay]
[No. of Trace Samples]
[Auto Repeat] Check, Box
[No. of Trace Execution]
[Trace Start on Monitor/Run
Mode] Check Box
[Trace Start Executing
Automatically After Download]
Check Box
*1: Settable Only on CJ2 CPU.
CX-Server PLC Tools_Page 54
Item
[Formula]
Select the conditions of Trigger completion.
When [Left Operand] is a bit (data type is BOOL).
↑ Falling Edge
↓ Rising Edge
[Left Operand] is other than the above:
= Equal
≠ Not equal *1
< Less than~ *1
> More than~ *1
≤ Maximum *1
≥ Minimum *1
[Right Operand]
Input the value to be Trigger. Input is enabled when [Left
Operand] is other than a bit (data type is except for BOOL).
Input delay value in sample number. Input in slider is possible.
When using all trace memory CPU Unit is not necessary, input
sampling number to be traced. Time per trace execution time will
be shorter. *1
Check the box when executing trace on auto repeat under the
same conditions.
Input the number of trace to be executed repeatedly. When
[Auto Repeat] check box is checked, input is enabled.
Start trace automatically at the timing when PLC mode changes
to Monitor mode, or Run Mode (includes Power on).*1
Check the box when starting Data Trace automatically after
transferring the execution conditions of Data Trace to PLC.
Function
OMRON