INSTALLATION & MAINTENANCE MANUAL
TNXTPEM

Advertisement

loading
Need help?

Need help?

Do you have a question about the TNXTPEM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Knightsbridge TNXTPEM

  • Page 1 INSTALLATION & MAINTENANCE MANUAL TNXTPEM...
  • Page 2: General Instructions

    These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following product: TNXTPEM SAFETY • This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations.
  • Page 3 • Ensuring correct polarity is observed, carefully wire as shown in Fig. 1. Two cables can be inserted into the push-fit terminal block in order to achieve loop-in/loop-out wiring. The earth terminal is non- functional and only provided for convenience Fig.
  • Page 4 Fig. 3 Fig. 3 Fig. 3 SENSOR LAYOUT SENSOR LAYOUT DIP SWITCH LAYOUT DIP SWITCH LAYOUT DIP SWITCH LAYOUT...
  • Page 5 DIP SWITCH SETTINGS When ambient light level is below open lux level, sensor automatically switches on lights at 100% brightness. When ambient light level is below open lux level, sensor automatically switches on lights at 100% brightness. When ambient light level is over close lux level, it switches off lights. When ambient light level is over close lux level, it switches off lights.
  • Page 6: Warranty

    WARNING This product must be disconnected from the circuit if subjected to any high voltage or insulatio testing. Irreparable damage will occur if this instruction is not followed. GENERAL GENERAL This product contains a light source of energy efficiency class D to Regulation (EU) No. 2019/2015 and (UK) This product contains a light source of energy efficiency class D to Regulation (EU) No.
  • Page 7 TESTING FOR EMERGENCY LUMINAIRES • Daily check – check LED charge indicator is illuminated • Monthly functional test - simulate a mains supply failure for approx. 30 seconds by operation of key switch or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator is illuminated •...
  • Page 8 SUPPLIED BY: (UK) MANUFACTURER ML ACCESSORIES LTD, UNIT E CHILTERN PARK, BOSCOMBE ROAD, DUNSTABLE LU5 4LT, WWW.MLACCESSORIES.CO.UK (EU) AUTHORISED REPRESENTATIVE SLV LIGHTING GROUP, DAIMLERSTRASSE 21-23, 52531 ÜBACH-PALENBERG, GERMANY EMAIL: EPREL@GROUP.SLV.COM MADE IN CHINA -20~ 230V IP20 35°C 50Hz HWOCT23_V1...