  • Page 2: Table Of Contents

    CONTENTS SAFETY INSTRUCTION ................3 COMPONENT IDENTIFICATION............7 INSTALLATION..................8 CONTROLS...................13 GENERATOR USE................13 PRE-OPERATION CHECK..............14 STARTING / STOPPING THE ENGINE..........16 MAINTENANCE..................17 TRANSPORTING AND STORAGE............20 TROUBLESHOOTING................21 WIRING DIAGRAM................23 SPECIFICATIONS.................24 EC DECLARATION OF CONFORMITY..........26 WARRANTY..................27 PRODUCT FAILURE................28 WARRANTY EXCLUSIONS..............29...
  • Page 3: Safety Instruction

    1. SAFETY INSTRUCTION WARNING: • Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! • Children should be protected by keeping them at a safe distance from the generator set! • Refilling of the generating sets are not allowed during the operation! •...
  • Page 4  Periodically check the installation of the connections and the tightness of the fixations, re-tightening them if necessary.  Clean the components of the air filter periodically, and replace the air filter when necessary.  Remove any electrical equipment that is plugged in before starting or stopping the generator.
  • Page 5  Do not overfill the tank with petrol to avoid spilling. If you notice a spill, it must be wiped up completely with a dry cloth before starting the motor.  If you swallow fuel by mistake, if you inhale fuel vapours or if you get drops of fuel in your eyes, see a doctor immediately.
  • Page 6  Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose.  The fuel for this machine is combustible and explosive. After stopping the machine, you must handle the remaining fuel correctly and meet local environmental requirements. ...
  • Page 7: Component Identification

    No use combustible diesel. NEVER use it at home or in partially enclosed areas such as garages ONLY use outdoors and away from open windows, doors and vents USING the generator in rain, snow, or near water can lead to electric shock. Keep the generator dry.
  • Page 8: Installation

    3. INSTALLATION 3.1 UNPACKING 1) Unpack all parts and lay them on a flat stable surface 2) Make sure the delivery contents are complete and free of damage. If you find that parts are missing or show damage, do not use the product but contact your dealer/service centre.
  • Page 9 BRACKET -Set the device up and down. -Attach the rubber foot as in the picture below!
  • Page 10 HANDLE -Put the device in its normal position. -Find holes on the frame for mounting the handle. -Put the handle in the holes. -Screw with nuts...
  • Page 11: Controls

    4. CONTROLS 4.1 ENGINE SWITCH To start and stop the engine. Switch position: • OFF: To Stop the engine. • ON: To run the engine after starting. 4.2 RECOIL STARTER To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. NOTICE: Do not allow the starter to snap back against the engine.
  • Page 12 The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke lever or choke rod manually. Move the lever or the rod to the CLOSE position to enrich the mixture. 4.5 CIRCUIT BREAKER The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle.
  • Page 13: Generator Use

    5. GENERATOR USE 5.1 CONNECTIONS TO A BUILDING’S ELECTRICAL SYSTEM Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. WARNING Improper connections to a building's electrical system, can allow electrical current from the generator to feedback into the utility lines.
  • Page 14: Pre-Operation Check

    Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF, but will shorten the service life of the generator. Limit operation requiring maximum power to 30 minutes. For continuous operation, do not exceed the rated power. In any case, the total power requirements (VA) of all appliances connected must be considered.
  • Page 15 Use 4-stroke oil, or equivalent high detergent, premium quality motor oil certified to meet or exceed U.S. automobile manufacturer’s requirements for Service Classification SG, SF/CC, CD. Motor oils classified SG, SF/CC, CD will show this designation on the container. SAE 10W-30 is recommended for general temperature use. Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range.
  • Page 16: Starting/Stopping The Engine

    If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of gasoline. If spark knock or pinging persists, see an authorized generator dealer. NOTICE Running the engine with persistent spark knock or pinging can cause engine damage. Running the engine with persistent spark knock or pinging is misuse, and the Distributor's Limited Warranty does not cover parts damaged by misuse.
  • Page 17: Maintenance

    8. MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. WARNING Exhaust gas contains poisonous carbon modoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated.
  • Page 18 NOTE: Diagrams may vary according to the types. 8.3 ENGINE OIL CHANGE Drain the oil while the engine is warm to assure complete and rapid draining 1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil 2.
  • Page 19 1) Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element. 2) Wash the element in a solution of household detergent and warm water, then rinse thoroughly; or wash in nonflammable or high flash point solvent. Allow the element to dry thoroughly 3) Soak the element in clean engine oil and squeeze out the excess oil.
  • Page 20: Transporting And Storage

    The gap should be: 0.70-0.80 mm (0.028-0.031 in). 6) Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 7) After the spark plug is seated, tighten with a spark plug wrench to compress the washer. If installing a new spark plug, tighten I/2 turn after the spark plug seats to compress the washer.
  • Page 21 1) Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. WARNING Gasoline is extremely flammable and is explosive under certain conditions. Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure.
  • Page 22: Troubleshooting

    10. TROUBLESHOOTING When the engine will not start: Is there fuel in the tank? Refill the fuel tank Is there oil in the tank? Add the recommended oil. STILL SPARK Is there spark from Replace the Take the generator to an spark plug.
  • Page 23: Wiring Diagram

    No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON NO DEFECTS Check the electrical appliance or Take the generator to an equipment for any defects. authorized generator dealer. Replace the electrical appliance DEFECTS or equipment.
  • Page 24 11. CIRCUIT DIAGRAM...
  • Page 25: Specifications

    12. SPECIFICATIONS Engine Engine model LB190F Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 420cc Rated speed 3600/min Igniting system Transistor magneto Starting system Recoil Fuel Volume (L) 25 L Continuous operation time (h) Min. Fuel consumption (g/kW.h) 360 g/kWh Lube Oil capacity (L) 1.1L...
  • Page 26: Ec Declaration Of Conformity

    Declaration of conformity BUILDER SAS ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: Gasoline Generator HG4000-PL Model: Serial number 20211243022-20211243271 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws...
  • Page 27: Warranty

    14. WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identified as defective by the designated distributor.
  • Page 28: Product Failure

    15. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank if your product has one. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 29: Warranty Exclusions

    16. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...