11.
SYNC Level Adjustment (VC-112 board)
[Suber
__—(Netequied
Cid
F Measurement Point [Pin @ of
CNTOI(CAMY) |
05 (VREFY)
Adjusting method:
1)
Release the protect.
Page: 6, address: 00, data: 01
2)
Set data: 05 to page: 6, address: 01, and press the PAUSE
button of the adjusting remote control unit.
(IRIS CLOSE mode setting)
3)
Change the data of page: F, address: 06, and adjust so that
the SYNC level (A) becomes the specified value.
4)
Press the PAUSE button of the adjusting remote control
unit.
Measurement Point
Processing after completing adjustments
1)
Set data: 00 to page: 6, address: 01, and press the PAUSE
button of the adjusting remote control unit.
(Release of IRIS CLOSE mode)
Pedestal level center
ee
ot
=
Fig. 7-8.
12.
BURST Level Adjustment (VC-112 board)
[Sitjet «di Newrequied
Sd
Adjusting method:
1)
Release the protect.
Page: 6, address: 00, data: 01
2)
Set data: 05 to page: 6, address: 01, and press the PAUSE
button of the adjusting remote control unit.
(IRIS CLOSE mode setting)
3)
Change the data of page: F, address: 07, and adjust so that
the burst level (A) becomes the specified value.
4)
Press the PAUSE button of the adjusting remote control
unit.
Processing after completing adjustments
1)
Set data: 00 to page: 6, address: 01, and press the PAUSE
button of the adjusting remote control unit.
(Release of IRIS CLOSE mode)
— 202 —