4.
28 MHz Original Oscillation Adjustment
(VC-112 board)
Adjusting method:
1)
Use CT801 to adjust the oscillation frequency to 14318181
+ 71 Hz.
5.
V SUB Adjustment (VC-112 board)
Adjusting method:
1)
Release the protect.
Page: 6, address: 00, data: 01
2)
Change the data of page: F, address: 04, and adjust the
voltage of pin @ of CN701 to (imager display voltage) +
0.1 Vde.
3) Press the PAUSE button of the adjusting remote control
unit.
(Example)
VC-112 board
When the display is 3P, the
VRG voltage specified value
CCDi
=2.0
+ 0.1
Vdc,
and
the
mneeer
VSUB voltage specified value
CD-84 board hole
=13.5 +0.1 Vde.
a
Vsus voltage
( 3P}
code address
VRG voltage code address
N<KXE<CCHODOVZEZR
ACTION
1
2
3
4
5
6
7
Fig. 7-7.
6. VRG Adjustment (VC-112 board)
a Cr
Pin © of CN701 6 CONT)
Digital voltmeter
,
Adjustment Page
Adjustment Address
05 (VRG)
Specified Value
(Imager display voltage) + 0.1 Vdc
Adjusting method:
1) _ Release the protect.
Page: 6, address: 00, data: 01
2)
Change the data of page: F, address: 05, and adjust the
voltage of pin @ of CN701 to (imager display voltage) +
0.1 Vde.
3)
Press the PAUSE button of the adjusting remote control
unit.
7.
CCD Imager Correction Data Write
[Dio 20 (CCD DEFECT
Perform CCD imager correction data write in the following
cases.
1. When the CCD imager has been replaced
2. The ocassion of exchaning 2 camera micro processor or
EEPROM (1C712).
3. When the page F data has been initialized
In the case of 1, as the correction data is not required for the
CCD imager for repair, adjust all data of addresses 1D to 2C to
"00".
In the case of 2 and 3, write the correction data attached to the
shield case of DD-47 board to addresses 1D to 2C.
If the correction data are not attached, adjust all data of addresses
1D to 2C to "00".
Adjusting method:
1)
Release the protect.
Page: 6, address: 00, data: 01
2)
Write the correction data to page: F, addresses: 1D to 2C.
Note: To perform write to the non-volatile memory, press
the PAUSE button of the adjusting remote control
unit before changing addresses.
Processing after completing adjustments
1)
If the CCD
imager has been replaced, remove the old
correction data label attached on the shield case (UPPER) of
DD-47 board.
— 199 —