3-4. VIDEO SYSTEM ADJUSTMENTS

Video system adjustments must be performed in the following order.
[Adjusting Order]
1.
28MHz origin oscillation adjustment
2.

AFC f

adjustment
0
3.
Filter f
adjustment
0
4.
Y OUT level adjustment
5.
C OUT level adjustment
6.
RP filter f
adjustment
0
7.
REC Y current adjustment
8.
REC L level adjustment
9.
REC C current adjustment
1. 28 MHz Origin Oscillation Adjustment (VC-214 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Mode
VTR stop
Signal
No signal
Pin #™ of IC301 or pin !™ of IC501
Measurement Point
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
40
Pin #™ of IC301 :
Specified Value
Pin !™ of IC501 :
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 61, and set data: 30.
4)
Select page: F, address: 40, change the data and set the clock
frequency (f) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 6, address: 61, and set data: 10.
7)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
VC-214 BOARD
48
33
49
32
IC301
64
17
1
16
f=4433594 ± 17Hz
f=14187500 ± 55Hz
25
36
24
37
IC501
13
48
12
1
2. AFC f

Adjustment (VC-214 board)

0
Adjust the pull-in range of the A/D converted clock generator during
playback.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 4D, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 6A, change the data and set the DC
voltage (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
5-35
VTR stop
No signal
Pin 4 of CN910 (AFC f0)
Digital voltmeter
F
6A
A=2.00 ± 0.05Vdc