MN009418A01-AD
Chapter 4: IMPRES 2 Batteries and Chargers
4.3
IMPRES 2 Battery with Self-Calibration and
Recondition
4.4
End-of-Service-Life Indication
The IMPRES 2 charger may indicate IMPRES 2 battery end-of-service by alternating red and green LED
upon successful completion of calibration or reconditioning. For battery with Self-Calibration icon, the charger
may indicate the battery End-of-Service momentarily at battery insert, and continuously blinks red and green
LED upon complete charging.
When batteries are used, normal wear reduces available capacity. IMPRES 2 chargers compare IMPRES 2
battery capacity to the battery-rated capacity. When the capacity is at a very low value, the IMPRES 2 battery
may be nearing its end-of-service. The IMPRES 2 battery remains usable. In some scenarios, it may be
preferable to deploy the battery to someone who does not require large battery capacity to complete a work
shift.
14
ATTENTION: IMPRES 2 batteries that have this icon on the battery label do
not require periodic calibration and reconditioning when docked into this IM-
PRES 2 charger (with software version V2.01 or newer).
NOTE: Ensure that your charger is always updated with the latest firmware.
The Motorola Solutions Charger Reprogrammer application package can be
downloaded from Motorola Online (MOL) or the Motorola Solutions website.