V. CARE AND MAINTENANCE (continued)
V. g - REPLACING THE GASKETS
To replace the gasket, grasp it firmly by one corner and pull
it out. Before attempting to install a new gasket, both the unit
and gasket must be at room temperature. Insert the four
corners first by using a rubber mallet (or hammer with a block
of wood). After the corners are properly inserted, work your
way towards the center from both ends by gently hitting with
a mallet until the gasket is completely seated in place (see
figure 14 for proper gasket placement).
Inside Door
Retainer Gasket
Foam
Outside Door
Stainless Steel Door Shown
Fig. 14
V. h - PREPARING FOR EXTENDED SHUTDOWN
If the refrigerator is not to be used for an extended period
of time, disconnect the electrical power supply and open
the doors. As soon as the cabinet has warmed up to room
temperature, wipe out the interior. Leave the doors open and
check again to make sure that no moisture has collected on
any parts. To restart refrigerator, follow instructions under
PRESTART CHECKS and OPERATION.
VI. CONTROL BASICS
Your new Centerline Refrigerator or Freezer is equipped with
a digital control, which precisely regulates operation. It is
supplied from the factory completely ready for use.
VI. a - INFORMATION MENU
The information available in this menu is:
* displayed only if enabled (see Configuration Parameters)
** displayed only if ACC > 0
Access to menu and information displayed:
• Press and immediately release button
• With button
• Press button
• To exit from the menu, press button
Initiate Stand-By:
Keeping the button
controller to be put on a standby or output control to be
resumed (with SB=YES only).
Locking the Keypad:
The keypad lock avoids undesired, potentially dangerous
operations, which might be attempted when the controller is
operating in a public place. In the INFO menu, set parameter
LOC = YES to inhibit all functions of the buttons. To resume
normal operation of keypad, adjust setting so that LOC = NO.
VI. b - ADJUSTING CABINET SETPOINT
Setpoint display and modification:
• Press button
setpoint value.
• While keeping the
or
to set the desired value (adjustment is within
the minimum SPL and the maximum SPH limit).
• When button
-8-
or
select the data to be displayed.
to display value.
or wait for 10 seconds.
pressed for 3 seconds allows the
for at least a half second to display the
button pressed, use button
is released, the new value is stored.
.