•
Outdoor units must be installed such that there is no short circuit of the hot discharge air or obstruction to smooth air fl ow.
Select the coolest possible place where intake air should not be hotter than the outside temperature (refer to operating range)
A
Air
Inlet
Condensed Water Disposal Of Outdoor Unit
(Heat Pump Unit Only)
•
There are 2 holes on the base of Outdoor Unit for condensed
water to fl ow out. Insert the drain elbow to one of the holes.
•
To install the drain elbow, fi rst insert one portion of the
hook to the base (portion A), then pull the drain elbow in
the direction shown by the arrow while inserting the other
portion to the base. After installation, check to ensure that
the drain elbow clings to base fi rmly.
•
If the unit is installed in a snowy and chilly area, condensed
water may freeze in the base. In such case, please remove
plug at the bottom of unit to smooth the drainage.
1 IM-5CCC-0912(0)-DAIKIN_EN.indd10 10
1 IM-5CCC-0912(0)-DAIKIN_EN.indd10 10
INSTALLATION CLEARANCE
B
Air
Discharge
All Model
Minimum Distance (mm)
1-10
C
Air
Inlet
A
B
C
D
300
1000
300
500
PLUG
A
BASE
DRAIN ELBOW
DRAIN ELBOW
D
Service
Space
10/9/12 4:11:09 PM
10/9/12 4:11:09 PM