Download Print this page

Advertisement

Quick Links

INSTALLATION
MANUAL
R410A SPLIT SERIES
MODELS
FTNV20JVAK
FTNV25JVAK
FTNV30JVAK
FTYNV20JVAK
FTYNV25JVAK
FTYNV30JVAK
FTS20JVAK
FTS25JVAK
FTYS20JVAK
FTYS25JVAK
RNV20JVAK
RNV25JVAK
RNV30JVAK
RYNV20JVAK
RYNV25JVAK
RYNV30JVAK
RS20JVAK
RS25JVAK
RYS20JVAK
RYS25JVAK
Installation Manual
R410A Split Series
IM-5WMJ(R)-0714(2)-DAIKIN(SASO)
Part No.: R08019040624B
English

Advertisement

loading
Need help?

Need help?

Do you have a question about the FTNV20JVAK and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FTNV20JVAK

  • Page 1 INSTALLATION MANUAL R410A SPLIT SERIES MODELS FTNV20JVAK RNV20JVAK FTNV25JVAK RNV25JVAK FTNV30JVAK RNV30JVAK Installation Manual FTYNV20JVAK RYNV20JVAK English R410A Split Series FTYNV25JVAK RYNV25JVAK FTYNV30JVAK RYNV30JVAK FTS20JVAK RS20JVAK FTS25JVAK RS25JVAK FTYS20JVAK RYS20JVAK FTYS25JVAK RYS25JVAK IM-5WMJ(R)-0714(2)-DAIKIN(SASO) Part No.: R08019040624B...
  • Page 3 OUTLINE AND DIMENSIONS Indoor Unit THE MARK SHOWS PIPING DIRECTION REAR REAR LEFT RIGHT TOP VIEW NAME PLATE SIGNAL RECEIVER TERMINAL BLOCK WITH EARTH SIDE VIEW BOTTOM BOTTOM TERMINAL INDOOR UNIT LOUVER ON/OFF SWITCH FRONT GRILLE FIXED SCREWS (INSIDE) ROOM TEMPERATURE THERMISTOR (INSIDE) FRONT VIEW All dimensions are in mm...
  • Page 4 Indoor Unit SCREW SCREW SCREW SCREW SCREW Through the wall WM3035J WM3035J hole Ø 65mm SCREW SCREW Gas pipe Liquid pipe Drain hose position INSTALLATION PLATE FTD30/36 All dimensions are in mm Dimension Model FT(Y)NV30 1289 Outdoor Unit All dimensions are in mm Dimension Model R(Y)NV20/25...
  • Page 5 Outdoor Unit All dimensions are in mm MADE IN MALAYSIA Dimension Model R(Y)NV30 1030 826...
  • Page 6 INSTALLATION MANUAL This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirements. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • Page 7 2. Pull out the unit from the other side. • Outdoor Unit 1. After takeoff the bands, pull out the carton box from the top side of the unit. * This product is not designed for re-packing. In case of re-packing, contact to Daikin Dealer.
  • Page 8 INSTALLATION DIAGRAM Indoor unit Cut thermal insulation pipe to an appropriate length and 75mm or more from ceiling Caulk pipe wrap it with tape, making hole gap sure that no gap is left in the with putty. Front panel insulation pipe’s cut line. Wrap the insulation pipe with the finishing tape from bottom 50mm or more from walls...
  • Page 9 Condensed Water Disposal Of Outdoor Unit (Heat Pump Unit Only) • There are 2 holes on the base of Outdoor Unit for PLUG condensed water to flow out. Insert the drain elbow to one of the holes. • To install the drain elbow, first insert one portion of the hook to the base (portion A), then pull the drain elbow in BASE the direction shown by the arrow while inserting the other...
  • Page 10 Bottom or side piping (For FTS/FTYS only) Cut off pipe port cover with a copping saw. ü For bottom piping: On the bottom of the front grille ü For side piping: On the side cover (front grille side and unit side) Apply the blade of the copping saw to the notch, and cut off the pipe port cover along the uneven inner surface.
  • Page 11 Mounting Installation Plate Mount The Unit Onto The Installation Plate Ensure that the wall is strong enough to withstand the weight Hook the indoor unit onto the upper portion of the installation of the unit. Otherwise, it is necessary to reinforce the wall plate (Engage the two hooks at the rear top of the indoor unit with plates, beams or pillars.
  • Page 12 REFRIGERANT PIPING Allowable Piping Length and Maximum No. of Bends If the pipe is too long, both the capacity and reliability of the unit will drop. As the number of bends increases, resistance to the flow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective. Always choose the shortest path and follow the recommendations as tabulated below: Indoor unit Outdoor Unit...
  • Page 13 REFRIGERANT PIPING Piping Works And Flaring Technique Figure I • Do not use contaminated or damaged copper tubing. If Cutting Copper Tube any piping, evaporator or condenser had been exposed or had been opened for 15 seconds or more, the system must 1/4t be vacuumed.
  • Page 14 ELECTRICAL WIRING CONNECTION IMPORTANT : * The figures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also subject to the type of installation and conductors used.
  • Page 15 • All wires must be fi rmly connected. • All wires must not touch the refrigerant piping, compressor or any moving parts of the fan motor. • The connecting wires between the indoor unit and the outdoor unit must be clamped on the wire clamps. •...
  • Page 16 VACUUMING AND CHARGING Vacuuming is necessary to eliminate all moisture and air from the system. Vacuuming The Piping And The Indoor Unit Except for the outdoor unit which is pre-charged with Refrigerant Piping Allen key Flare nut refrigerant, the indoor unit and the refrigerant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle may cause malfunction of the compressor.
  • Page 17 ADDITIONAL CHARGE The refrigerant is pre-charged in the outdoor unit. If the piping length is less than 7.5m, then additional charge after vacuuming is not necessary. If the piping length is more than 7.5m, then use the additional charge value as indicated in the table. Additional refrigerant charge [g] per additional 1m length as tabulated (For R410A models) Indoor FT(Y)NV/FT(Y)S20/25...
  • Page 18 LED Indicator Lights: Normal Operation And Fault Conditions For Cooling/Heat Pump Unit (For FT(Y)NV20/25 only) Operation COOL/HEAT (BLUE/RED) Cool mode BLUE Heat mode Auto mode in Heating operation Auto mode in Cooling operation BLUE Timer on Sleep mode on Fan mode on BLUE Dry mode on BLUE...
  • Page 19 LED Indicator Lights: Normal Operation And Fault Conditions For Cooling/Heat Pump Unit (For FT(Y)S20/25 only) Operation COOL/HEAT/TIMER (BLUE/RED/VIOLET) Cool mode BLUE Heat mode Auto mode in Heating operation Auto mode in Cooling operation BLUE Timer on VIOLET Fan mode on BLUE Dry mode on BLUE...
  • Page 20 AIR CONDITIONER UNIT OPERATION Dry Mode Notes On Flaps And Louvers Angles • When the air humidity is high, the unit can operate in dry • When “SWING button” is selected, the flaps swinging mode. Press <MODE> button and choose <DRY>. range depends on the operation mode.
  • Page 21 AIR FILTER Open the front panel. Clean or replace each filter. • Hold the panel at the recesses on the main unit (2 recesses See figure. on right and left sides) and lift it until it stops. • When shaking off remaining water, do not wring the filter. Air fi...
  • Page 22 SERVICE AND MAINTENANCE Service Parts Maintenance Procedures Period Indoor air filter Remove any dust adhering to the filter by using a vacuum cleaner or wash in lukewarm At least once water (below 40°C/104°F) with a neutral cleaning detergent. every 2 weeks. Rinse the filter well and dry before placing it back onto the unit.
  • Page 23 ! CAUTION • Don’t touch the metal parts of the indoor unit. It may cause an injury. • When removing or attaching the front panel, support the panel securely with hand to prevent it from falling. • For cleansing, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.
  • Page 24 INDOOR UNIT 13.0 14.0 16.0 13.0 14.0 OUTDOOR UNIT REFRIGERANT R410A 1.45 2.00 2.60 1.45 2.00 Malaysia COUNTRY OF ORIGIN INDOOR UNIT Malaysia OUTDOOR UNIT NOTE: This product is not designed for repacking. In case of re-packing, contact to Daikin Dealer.
  • Page 26 Kita-ku, Osaka, 530-8323 Japan Tokyo offi ce: JR Shinagawa East Bldg., 2-18-1, Konan, P.O.Box 18674, Galleries 4, 11th Floor, Minato-ku, Tokyo, 108-0075 Japan Downtown Jebel Ali, Dubai, UAE. http://www.daikin.com/global/ Importer for Turkey Hürriyet Mahallesi Yakacık D-100 Kuzey Yanyol Caddesi No:49/1-2 Kartal − İstanbul...
  • Page 27 Kita-ku, Osaka, 530-8323 Japan Tokyo office: JR Shinagawa East Bldg., 2-18-1, Konan, P.O.Box 18674, Galleries 4, 11th Floor, Minato-ku, Tokyo, 108-0075 Japan Downtown Jebel Ali, Dubai, UAE. http://www.daikin.com/global/ Importer for Turkey Hürriyet Mahallesi Yakacık D-100 Kuzey Yanyol Caddesi No:49/1-2 Kartal − İstanbul...
  • Page 29 ‫ﺍﻟﻤﻮﺻﻔﺎﺕ‬ ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬ FTS25JVAK FTS20JVAK FTNV30JVAK FTNV25JVAK FTNV20JVAK ‫ﺍﻟﻤﻮﺩﻳﻞ‬ ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬ RS25JVAK RS20JVAK RN30JVAK RS25JVAK RS20JVAK ‫ﻓﻮﻟﺖ‬ ‫ﺍﻟﻔﻮﻟﻄﻴﺔ ﺍﻟﻤﻘﺪﺭﺓ‬ ‫ﻫﺮﺗﺰ‬ ‫ﺍﻟﺘﺮﺩﺩ ﺍﻟﻤﻘﺪﺭ‬ ‫ﺃﻣﺒﻴﺮ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻤﻘﺪﺭ‬ 8.41 6.49 10.10 8.41 6.49 ‫ﺍﻟﺘﺒﺮﻳﺪ‬ (T1) ‫ﻛﻴﻠﻮ ﻭﺍﻁ‬ ‫ﺩﺧﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻘﺪﺭ‬ 1.92 1.48 2.30 1.92...
  • Page 30 ‫ﺗﻨﺒﻴﻪ‬ .‫ﻻ ﺗﻠﻤﺲ ﺍﻻﺟﺰﺍﺀ ﺍﻟﻤﻌﺪﻧﻴﺔ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ. ﻳﻤﻜﻦ ﺍﻥ ﻳﺴﺒﺐ ﺫﻟﻚ ﺟﺮﻭﺣﺎﺕ‬ • .‫ﻋﻨﺪ ﻧﺰﻉ ﺍﻭ ﺗﺮﻛﻴﺐ ﺍﻟﻠﻮﺣﺔ ﺍﻻﻣﺎﻣﻴﺔ، ﺍﺩﻋﻢ ﺍﻟﻠﻮﺣﺔ ﺑﺼﻮﺭﺓ ﺁﻣﻨﺔ ﺑﻮﺍﺳﻄﺔ ﺍﻟﻴﺪ ﻭﺫﻟﻚ ﻟﻤﻨﻊ ﺳﻘﻮﻁ ﺍﻟﻠﻮﺣﺔ‬ • • ،‫ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ، ﻭﻻ ﺗﺴﺘﻌﻤﻞ ﺍﻟﺒﻨﺰﻳﻦ، ﻭﺍﻟﻜﺎﺯ ﻭﺍﻟﺜﻨﺮ، ﻭﻻ ﺗﺴﺘﻌﻤﻞ ﺍﻟﺰﻳﻮﺕ ﺍﻟﻤﺘﻄﺎﻳﺮﺓ‬ ‫ﻟﻠﺘﻨﻈﻴﻒ،...
  • Page 31 ‫ﺍﻟﺘﺼﻠﻴﺢ ﻭﺍﻟﺼﻴﺎﻧﺔ‬ ‫ﺍﻟﻤﺪﺓ‬ ‫ﺍﺟﺮﺍﺀﺍﺕ ﺍﻟﺼﻴﺎﻧﺔ‬ ‫ﺍﻗﺴﺎﻡ ﺍﻟﺼﻴﺎﻧﺔ‬ ‫ﻣﺮﺷﺢ ﺍﻟﻬﻮﺍﺀ ﺍﻟﺪﺍﺧﻠﻲ‬ ‫ﻣﺮﺓ ﻭﺍﺣﺪﺓ ﻛﻞ ﺍﺳﺒﻮﻋﲔ ﻋﻠﻰ‬ ‫ﺍﺯﻝ ﺍﻱ ﻏﺒﺎﺭ ﻣﻠﺘﺼﻖ ﺑﺎﻟﻤﺮﺷﺢ ﺑﺎﺳﺘﻌﻤﺎﻝ ﻣﻜﻨﺴﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺍﻭ ﻧﻈﻔﹼ ﻪ ﺑﻤﺎﺀ ﺩﺍﻓﻲﺀ‬ .‫ﺍﻻﻗﻞ‬ .‫ﻣﻊ ﻣﺤﻠﻮﻝ ﺗﻨﻈﻴﻒ ﻣﺘﻌﺎﺩﻝ‬ ‫ﻣﺌﻮﻳﺔ‬ ‫ﺍﻗﻞ ﻣﻦ‬ ‫ﻗﻠﻴ ﻼ ﹰ‬ 40 ° .‫ﺯﻳﺎﺩﺓ...
  • Page 32 ‫ﻣﺮﺷﺢ ﺍﻟﻬﻮﺍﺀ‬ .‫ﻧﻈﹼ ﻒ ﺍﻭ ﺑﺪﻝ ﻛﻞ ﻣﺮﺷﺢ‬ ‫ﺍﻓﺘﺢ ﺍﻟﻠﻮﺣﺔ ﺍﻻﻣﺎﻣﻴﺔ‬ .‫ﺍﻧﻈﺮ ﺍﻟﺸﻜﻞ‬ ‫ﺍﻣﺴﻚ ﺍﻟﻠﻮﺣﺔ ﻣﻦ ﺍﻟﺘﺠﺎﻭﻳﻒ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺮﺋﻴﺴﻴﺔ‬ • .‫ﻋﻨﺪ ﻧﻔﺾ ﺍﻟﻤﺎﺀ ﺍﻟﻤﺘﺒﻘﻲ ﻋﻠﻰ ﺍﻟﻤﺮﺷﺢ، ﻻ ﺗﻌﺼﺮ ﺍﻟﻤﺮﺷﺢ‬ .‫ﻭﺍﺭﻓﻊ ﺍﻟﻠﻮﺣﺔ ﺣﺘﻰ ﺗﺘﻮﻗﻒ‬ ‫ﺗﺠﻮﻳﻒ ﻋﻠﻰ ﺍﻟﺠﺎﻧﺐ ﺍﻻﻳﺴﺮ ﻭﺍﻻﻳﻤﻦ‬ •...
  • Page 33 ‫ﺗﺸﻐﻴﻞ ﻭﺣﺪﺓ ﻣﻜﻴﻔﺔ ﺍﻟﻬﻮﺍﺀ‬ ‫ﺍﻟﻮﺿﻊ ﺍﻟﺠﺎﻑ‬ ‫ﻣﻼﺣﻈﺎﺕ ﺣﻮﻝ ﻗﻼﺑﺎﺕ ﺍﻟﻬﻮﺍﺀ ﻭﺯﻭﺍﻳﺎ ﺷﻘﻮﻕ ﺍﻟﺘﻬﻮﻳﺔ‬ ‫ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺍﻟﺮﻃﻮﺑﺔ ﻋﺎﻟﻴﺔ ﻓﻲ ﺍﻟﺠﻮ، ﻳﻤﻜﻦ ﺗﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ ﺑﺎﻟﻮﺿﻊ‬ • ‫، ﻳﻌﺘﻤﺪ ﻣﺪﻯ‬ ‫ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﺍﺧﺘﻴﺎﺭ ﺯﺭ ﺗﺄﺭﺟﺢ ﺍﻟﻬﻮﺍﺀ‬ • “SWING button” ‫ﻭﺍﺧﺘﺮ‬ ‫ﺍﻟﺠﺎﻑ. ﺍﺿﻐﻂ ﺯﺭ‬ <DRY>...
  • Page 34 ‫ﻓﻘﻂ‬ ‫ﺇﻟﻰ‬ ‫ﻭﺣﺪﺓ ﺿﺦ ﺍﻟﺘﺪﻓﺌﺔ‬ ‫: ﺣﺎﻻﺕ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻌﺎﺩﻱ ﻭﺍﻟﺨﺎﻃﻲﺀ ﻟﻮﺣﺪﺓ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺍﺿﻮﺍﺀ ﻣﺆﺷﺮ‬ FT(Y)S20/25 ‫ﺍﻟﻌﻤﻠﻴﺔ‬ ‫ﺍﻟﻤﺆﻗﺖ‬ ‫ﺍﻟﺤﺮﺍﺭﺓ‬ ‫ﺗﺒﺮﻳﺪ‬ ‫ﺑﻨﻔﺴﺠﻲ‬ ‫ﺍﺣﻤﺮ‬ ‫ﺃﺯﺭﻕ‬ ‫ﻭﺿﻊ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺃﺯﺭﻕ‬ ‫ﻭﺿﻊ ﺍﻟﺤﺮﺍﺭﺓ‬ ‫ﺍﺣﻤﺮ‬ ‫ﺍﻟﻮﺿﻊ ﺍﻟﺘﻠﻘﺎﺋﻲ ﻓﻲ ﻋﻤﻠﻴﺔ ﺍﻟﺘﺪﻓﺌﺔ‬ ‫ﺍﺣﻤﺮ‬ ‫ﺍﻟﻮﺿﻊ ﺍﻟﺘﻠﻘﺎﺋﻲ ﻓﻲ ﻋﻤﻠﻴﺔ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺃﺯﺭﻕ‬ ‫ﺗﺸﻐﻴﻞ...
  • Page 35 ‫ﻓﻘﻂ‬ ‫ﺇﻟﻰ‬ ‫ﻭﺣﺪﺓ ﺿﺦ ﺍﻟﺘﺪﻓﺌﺔ‬ ‫: ﺣﺎﻻﺕ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻌﺎﺩﻱ ﻭﺍﻟﺨﺎﻃﻲﺀ ﻟﻮﺣﺪﺓ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺍﺿﻮﺍﺀ ﻣﺆﺷﺮ‬ FT(Y)NV20/25 ‫ﺍﻟﻌﻤﻠﻴﺔ‬ ‫ﺗﺪﻓﺌﺔ‬ ‫ﺗﺒﺮﻳﺪ‬ ‫ﺃﺯﺭﻕ‬ ‫ﺍﺣﻤﺮ‬ ‫ﻭﺿﻊ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺃﺯﺭﻕ‬ ‫ﻭﺿﻊ ﺍﻟﺤﺮﺍﺭﺓ‬ ‫ﺍﺣﻤﺮ‬ ‫ﺍﻟﻮﺿﻊ ﺍﻟﺘﻠﻘﺎﺋﻲ ﻓﻲ ﻋﻤﻠﻴﺔ ﺍﻟﺘﺪﻓﺌﺔ‬ ‫ﺍﺣﻤﺮ‬ ‫ﺍﻟﻮﺿﻊ ﺍﻟﺘﻠﻘﺎﺋﻲ ﻓﻲ ﻋﻤﻠﻴﺔ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺃﺯﺭﻕ‬ ‫ﺗﺸﻐﻴﻞ ﺍﻟﻤﺆﻗﺖ‬ ‫ﺗﺸﻐﻴﻞ...
  • Page 36 ‫ﺍﻟﺸﺤﻦ ﺍﻻﺿﺎﻓﻲ‬ ‫ﻡ، ﺍﺫﻥ ﻻﺣﺎﺟﺔ ﻟﺸﺤﻦ ﺍﺿﺎﻓﻲ ﺑﻌﺪ ﺍﻟﺘﻔﺮﻳﻎ. ﺍﺫﺍ ﻛﺎﻥ ﻃﻮﻝ ﺍﻷﻧﺎﺑﻴﺐ‬ ‫ﺍﻥ ﻣﺎﺩﺓ ﺗﺒﺮﻳﺪ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻣﺸﺤﻮﻧﺔ ﻣﺴﺒﻘ ﺎ ﹰ. ﺍﺫﺍ ﻛﺎﻥ ﻃﻮﻝ ﺍﻻﻧﺎﺑﻴﺐ ﺍﻗﻞ ﻣﻦ‬ 7،5 .‫ﻡ، ﺍﺳﺘﻌﻤﻞ ﺻﻤﺎﻡ ﺍﻟﺸﺤﻦ ﺍﻹﺿﺎﻓﻲ ﻛﻤﺎ ﻫﻮ ﻣﺒﻴﻦ ﻓﻲ ﺍﻟﺠﺪﻭﻝ‬ ‫ﺃﻛﺜﺮ ﻣﻦ‬ 7،5 ‫ﻟﻤﻮﺩﻳﻼﺕ‬...
  • Page 37 ‫ﺍﻟﺘﻔﺮﻳﻎ ﻭﺍﻟﺸﺤﻦ‬ .‫ﻳﻌﺘﺒﺮ ﺍﻟﺘﻔﺮﻳﻎ ﺿﺮﻭﺭﻳ ﺎ ﹰ ﻻﺯﺍﻟﺔ ﺍﻟﺮﻃﻮﺑﺔ ﻭﺍﻟﻬﻮﺍﺀ ﻣﻦ ﺍﻟﻨﻈﺎﻡ‬ ‫ﺗﻔﺮﻳﻎ ﺍﻷﻧﺎﺑﻴﺐ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬ ‫ﺍﻧﺎﺑﻴﺐ ﻣﺎﺩﺓ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﻣﻔﺘﺎﺡ‬ Allen ‫ﺻﻤﻮﻟﺔ ﺗﻮﺳﻴﻊ‬ ‫ﺑﺎﺳﺘﺜﻨﺎﺀ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺍﻟﺘﻲ ﺗﻢ ﺷﺤﻨﻬﺎ ﻣﺴﺒﻘ ﺎ ﹰ ﺑﻤﺎﺩﺓ ﺍﻟﺘﺒﺮﻳﺪ، ﻳﺠﺐ‬ ‫ﺗﻄﻬﻴﺮ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻧﺎﺑﻴﺐ ﺍﻟﺘﻮﺻﻴﻞ ﻣﻦ ﺍﻟﻬﻮﺍﺀ ﻷﻥ ﺍﻟﻬﻮﺍﺀ ﻳﺤﺘﻮﻱ‬ .‫ﻋﻠﻰ...
  • Page 38 .‫ﻳﺠﺐ ﺗﻮﺻﻴﻞ ﻛﺎﻓﺔ ﺍﻻﺳﻼﻙ ﺑﺎﺣﻜﺎﻡ‬ • .‫ﺗﺄﻛﺪ ﻣﻦ ﺃﻥ ﻛﺎﻓﺔ ﺍﻷﺳﻼﻙ ﺗﻜﻮﻥ ﻏﻴﺮ ﻣﻼﻣﺴﺔ ﻷﻧﺎﺑﻴﺐ ﺍﻟﻤﺒﺮﺩ، ﺃﻭ ﺍﻟﻀﺎﻏﻂ ﺃﻭ ﺃﻳﺔ ﺃﺟﺰﺍﺀ ﻣﺘﺤﺮﻛﺔ‬ • • .‫ﻳﺠﺐ ﺗﺜﺒﻴﺖ ﺳﻠﻚ ﺍﻟﺘﻮﺻﻴﻞ ﺑﻴﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺑﻮﺍﺳﻄﺔ ﺃﺩﻭﺍﺕ ﺗﺜﺒﻴﺖ ﺍﻷﺳﻼﻙ ﺍﻟﻤﺮﻓﻘﺔ‬ • .‫ﻭﺍﻟﺬﻱ ﻳﺘﻄﻠﺐ ﺍﻟﺤﺪ ﺍﻻﺩﻧﻰ‬ H07RN-F ‫ﻳﺠﺐ...
  • Page 39 ‫ﺗﻮﺻﻴﻞ ﺍﻻﺳﻼﻙ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﻭﺣﺪﺓ ﺍﻟﺘﺒﺮﻳﺪ‬ :‫ﻫﺎﻡ‬ ‫ﺍﻥ ﺍﻻﺭﻗﺎﻡ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻓﻲ ﺍﻟﺠﺪﻭﻝ ﻫﻲ ﻟﻐﺮﺽ ﺍﻻﻃﻼﻉ ﻓﻘﻂ. ﻳﺠﺐ ﻓﺤﺼﻬﺎ ﻭﺍﺧﺘﻴﺎﺭﻫﺎ ﺑﺤﻴﺚ ﺗﺘﻮﺍﻓﻖ ﻣﻊ ﺍﻟﺸﻔﺮﺍﺕ ﺍﻟﻤﺤﻠﻴﺔ ﺍﻟﻤﺄﻟﻮﻓﺔ. ﻫﺬﻩ‬ .‫ﺍﻳﻀ ﺎ ﹰ ﻋﺮﺿ ﺔ ﹰ ﻟﻨﻮﻉ ﺍﻟﻨﺼﺐ ﻭﺍﺳﺘﻌﻤﺎﻝ ﺍﻟﻤﻮﺻﻼﺕ‬ .‫ﻳﺠﺐ ﻓﺤﺺ ﻣﺪﻯ ﺍﻟﻔﻮﻟﻄﻴﺔ ﺍﻟﻤﻨﺎﺳﺐ ﻣﻊ ﻣﻌﻄﻴﺎﺕ ﺍﻟﻌﻼﻣﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ ﺍﻟﻮﺣﺪﺓ‬ ‫ﻃﻮﺭ...
  • Page 40 ‫ﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺍﻧﺠﺎﺯ ﺷﺒﻜﺔ ﺍﻻﻧﺎﺑﻴﺐ ﻭ ﺍﻟﺘﻮﺳﻴﻊ ﺍﻟﺘﻘﻨﻲ‬ ‫ﺍﻟﺸﻜﻞ‬ ‫ﻗﻄﻊ ﺍﻧﺒﻮﺏ ﺍﻟﻨﺤﺎﺱ‬ ،‫ﻻ ﺗﺴﺘﻌﻤﻞ ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺳﻴﺔ ﻣﻠﻮﺛﺔ ﺃﻭ ﻣﺘﻀﺮﺭﺓ. ﺇﺫﺍ ﺗﻢ ﻓﺘﺢ ﺃﻳﺔ ﺃﻧﺎﺑﻴﺐ‬ • ‫ﺕ‬ ‫ﺛﺎﻧﻴﺔ ﺃﻭ ﺃﻛﺜﺮ، ﻓﺎﻧﻪ ﻳﺠﺐ ﺗﻔﺮﻳﻎ‬ ‫ﺃﻭ ﺍﻟﻤﺒﺨﺮ ﺃﻭ ﺍﻟﻤﻜﺜﻒ ﻟﻤﺪﺓ‬ ‫ﺍﻟﻨﻈﺎﻡ. ﻋﺎﺩﺓ، ﻻ ﺗﻨﺰﻉ ﺍﻟﺒﻼﺳﺘﻚ، ﺍﻟﻘﻮﺍﺑﺲ ﺍﻟﻤﻄﺎﻃﻴﺔ ﻭﺍﻟﺼﻤﻮﻻﺕ‬ ‫ﺍﻟﻨﺤﺎﺳﻴﺔ...
  • Page 41 ‫ﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﺒﺮﻳﺪ‬ ‫ﺍﻟﻤﺴﻤﻮﺡ ﺑﻪ ﻃﻮﻝ ﺍﻷﻧﺎﺑﻴﺐ ﻭﺭﻗﻢ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻣﻦ ﺍﻟﻤﻨﺤﻨﻴﺎﺕ‬ ،‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ ﺍﻻﻧﺒﻮﺏ ﻃﻮﻳ ﻼ ﹰ ﺟﺪ ﺍ ﹰ، ﺳﻮﻑ ﺗﻘﻞ ﺍﻟﺴﻌﺔ ﻭﺍﻻﻋﺘﻤﺎﺩﻳﺔ ﻛﻠﻴﻬﻤﺎ. ﺑﺴﺒﺐ ﺯﻳﺎﺩﺓ ﻋﺪﺩ ﺍﻻﻧﺤﻨﺎﺀﺍﺕ، ﻭﺯﻳﺎﺩﺓ ﻧﻈﺎﻡ ﻣﻘﺎﻭﻣﺔ ﺍﻻﻧﺎﺑﻴﺐ ﻟﺘﺪﻓﻖ ﻣﺎﺩﺓ ﺍﻟﺘﺒﺮﻳﺪ‬ :‫ﻭﺑﺎﻟﺘﺎﻟﻲ ﺗﻨﺨﻔﺾ ﺳﻌﺔ ﺍﻟﺘﺒﺮﻳﺪ. ﻛﻨﺘﻴﺠﺔ ﻟﺬﻟﻚ، ﺗﺘﺄﺛﺮ ﺍﻋﺘﻤﺎﺩﻳﺔ ﺍﻟﻀﺎﻏﻄﺔ. ﺩﺍﺋﻤ ﺎ ﹰ ﺍﺧﺘﺮ ﺍﻗﺼﺮ ﻣﺴﺎﺭ ﻭﺍﺗﺒﻊ ﺍﻟﺘﻮﺻﻴﺎﺕ ﺍﻟﻤﺪﻭﻧﺔ ﺍﺩﻧﺎﻩ‬ ‫ﺍﻟﻮﺣﺪﺓ...
  • Page 42 ‫ﺗﺘﺜﺒﻴﺖ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﻟﻮﺣﺔ ﺍﻟﺘﺮﻛﻴﺐ‬ ‫ﻟﻮﺣﺔ ﺗﺜﺒﻴﺖ ﺍﻟﺘﺮﻛﻴﺐ‬ ‫ﺛ ﺒ ﹼﺖ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻋﻠﻰ ﺍﻟﻘﺴﻢ ﺍﻟﻌﻠﻮﻱ ﻟﻠﻮﺣﺔ ﺍﻟﺘﺮﻛﻴﺐ )ﺍﺭﺑﻂ ﺍﻟﻜﻼ ﹼ ﺑﻴﻦ‬ ،‫ﺗﺄﻛﺪ ﻣﻦ ﺍﻟﻘﻮﺓ ﺍﻟﻜﺎﻓﻴﺔ ﻟﻠﺠﺪﺍﺭ ﺑﺤﻴﺚ ﻳﺘﺤﻤﻞ ﻭﺯﻥ ﺍﻟﻮﺣﺪﺓ. ﺑﻄﺮﻳﻘﺔ ﺍﺧﺮﻯ‬ .(‫ﻓﻲ ﺍﻋﻠﻰ ﻣﺆﺧﺮﺓ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻣﻊ ﺍﻟﺤﺎﻓﺔ ﺍﻟﻌﻠﻮﻳﺔ ﻟﻠﻮﺣﺔ ﺍﻟﺘﺮﻛﻴﺐ‬ .‫ﻣﻦ...
  • Page 43 ‫ﺍﻷﻧﺎﺑﻴﺐ ﺍﻟﺴﻔﻠﻴﺔ ﺃﻭ ﺍﻟﺠﺎﻧﺒﻴﺔ‬ ‫ﻓﻘﻂ‬ ‫ﺇﻟﻰ‬ FTS/FTYS .‫ﺍﻗﻄﻊ ﻏﻄﺎﺀ ﻣﻨﻔﺬ ﺍﻷﻧﺒﻮﺏ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻨﺸﺎﺭ ﻗﺴﻄﻞ‬ ü ‫ﺑﺎﻟﻨﺴﺒﺔ ﻟﻸﻧﺎﺑﻴﺐ ﺍﻟﺴﻔﻠﻴﺔ:ﺃﺳﻔﻞ ﺍﻟﺸﺒﻜﺔ ﺍﻷﻣﺎﻣﻴﺔ‬ ü ‫ﺟﺎﻧﺐ ﺍﻟﺸﺒﻜﺔ ﺍﻷﻣﺎﻣﻲ ﻭﺟﺎﻧﺐ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺑﺎﻟﻨﺴﺒﺔ ﻟﻸﻧﺎﺑﻴﺐ ﺍﻟﺠﺎﻧﺒﻴﺔ: ﻋﻠﻰ ﺍﻟﻐﻄﺎﺀ ﺍﻟﺠﺎﻧﺒﻲ‬ .‫ﺿﻊ ﻧﺼﻞ ﻣﻨﺸﺎﺭ ﺍﻟﻘﺴﻄﻞ ﻋﻠﻰ ﺍﻟﺤﺰ، ﻭﺍﻗﻄﻊ ﻏﻄﺎﺀ ﻣﻨﻔﺬ ﺍﻷﻧﺒﻮﺏ ﻋﻠﻰ ﻃﻮﻝ ﺍﻟﺴﻄﺢ ﺍﻟﺪﺍﺧﻠﻲ ﻏﻴﺮ ﺍﻟﻤﺘﺴﺎﻭﻱ‬ ‫ﺟﺎﻧﺐ...
  • Page 44 ‫ﺍﻟﺘﺨﻠﺺ ﻣﻦ ﻣﺎﺀ ﺍﻟﺘﻜﺎﺛﻒ ﻟﻠﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬ (‫)ﻭﺣﺪﺓ ﻣﻀﺨﺔ ﺍﻟﺤﺮﺍﺭﺓ ﻓﻘﻂ‬ ‫ﻗﺎﺑﺲ‬ ‫ﻳﻮﺟﺪ ﺛﻘﺒﻴﻦ ﻋﻠﻰ ﻗﺎﻋﺪﺓ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻣﻦ ﺍﺟﻞ ﺍﻧﺴﻴﺎﺏ ﺍﻟﻤﺎﺀ‬ • .‫ﺍﻟﻤﺘﻜﺜﻒ. ﺍﺩﺧﻞ ﻣﺮﻓﻖ ﺍﻟﺘﺼﺮﻳﻒ ﻓﻲ ﺍﺣﺪ ﺍﻟﺜﻘﺒﻴﻦ‬ ‫ﻟﺘﺮﻛﻴﺐ ﻣﺮﻓﻖ ﺍﻟﺘﺼﺮﻳﻒ، ﺍﻭ ﻻ ﹰ ﺍﺩﺧﻞ ﺟﺰﺀ ﺍ ﹰ ﻭﺍﺣﺪ ﺍ ﹰ ﻣﻦ ﺍﻟﺨﻄﺎﻑ ﻓﻲ‬ •...
  • Page 45 ‫ﻣﺨﻄﻂ ﺍﻟﺘﺮﻛﻴﺐ‬ ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬ ‫ﺍﻗﻄﻊ ﺍﻧﺒﻮﺏ ﺍﻟﻌﺰﻝ ﺍﻟﺤﺮﺍﺭﻱ ﺑﻄﻮﻝ‬ ‫ﻣﻢ ﺍﻭ ﺍﻛﺜﺮ ﻣﻦ ﺍﻟﺴﻘﻒ‬ ‫ﻓﺮﺍﻍ ﺛﻘﺐ ﺍﻻﻧﺒﻮﺏ‬ ،‫ﻣﻨﺎﺳﺐ ﻭﻟﻔﻪ ﺑﻮﺍﺳﻄﺔ ﺷﺮﻳﻂ‬ ‫ﺍﻟﻤﺠﻠﻔﻂ ﻣﻊ‬ ‫ﻭﺗﺄﻛﺪ ﻣﻦ ﻋﺪﻡ ﺗﺮﻙ ﻓﺮﺍﻍ ﺩﺍﺧﻞ‬ .‫ﺍﻟﻤﻌﺠﻮﻧﺔ‬ ‫ﺍﻟﻠﻮﺣﺔ ﺍﻻﻣﺎﻣﻴﺔ‬ .‫ﺧﻂ ﻗﻄﻊ ﺍﻧﺒﻮﺏ ﺍﻟﻌﺰﻝ‬ ‫ﻟﻒ ﺍﻧﺒﻮﺏ ﺍﻟﻌﺰﻝ ﺑﻮﺍﺳﻄﺔ ﺷﺮﻳﻂ‬ ‫ﻣﻢ...
  • Page 46 .‫ﺑﻌﺪ ﻧﺰﻉ ﺍﻷﺣﺰﻣﺔ ﻭﺳﺤﺐ ﺍﺣﺪ ﺍﻟﻤﺴﺎﻧﺪ ﺍﻟﺠﺎﻧﺒﻴﺔ، ﺍﺩﻓﻊ ﺍﻟﻮﺣﺪﺓ ﺇﻟﻰ ﺍﻟﺠﺎﻧﺐ ﺍﻟﻤﻌﺎﻛﺲ‬ .‫ﺍﺳﺤﺐ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺍﳉﺎﻧﺐ ﺍﻵﺧﺮ‬ ‫ﺍﻟﻮﺣﺪﺓ ﺍﳋﺎﺭﺟﻴﺔ‬ • .‫ﺑﻌﺪ ﻧﺰﻉ ﺍﻷﺣﺰﻣﺔ، ﺍﺳﺤﺐ ﺻﻨﺪﻭﻕ ﺍﻟﻜﺮﺗﻮﻥ ﻣﻦ ﺍﳉﺎﻧﺐ ﺍﻟﻌﻠﻮﻱ ﻟﻠﻮﺣﺪﺓ‬ ‫ﺍﻟﺘﻐﻠﻴﻒ. ﻓﻲ ﺣﺎﻟﺔ ﺇﻋﺎﺩﺓ - ﺍﻟﺘﻐﻠﻴﻒ، ﺍﺗﺼﻞ ﺑﻮﻛﻴﻞ‬ ‫ﻫﺬﺍ ﺍﳌﻨﺘﺞ ﻏﻴﺮ ﻣﺼﻤﻢ ﻹﻋﺎﺩﺓ‬ Daikin ٥...
  • Page 47 ‫ﻛﺘﻴﺐ ﺍﻟﺘﺮﻛﻴﺐ‬ .‫ﻳﺰﻭﺩﻙ ﻫﺬﺍ ﺍﻟﻜﺘﻴﺐ ﺑﻄﺮﻕ ﺍﻟﺘﺮﻛﻴﺐ ﻟﻀﻤﺎﻥ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻌﺎﺩﻱ ﺍﻟﺠﻴﺪ ﻭﺍﻟﻤﺄﻣﻮﻥ ﻟﻮﺣﺪﺓ ﻣﻜﻴﻔﺔ ﺍﻟﻬﻮﺍﺀ‬ .‫ﻗﺪ ﻳﻜﻮﻥ ﻣﻦ ﺍﻟﻀﺮﻭﺭﻱ ﺍﺟﺮﺍﺀ ﺿﺒﻂ ﺧﺎﺹ ﻟﻜﻲ ﻳﻼﺋﻢ ﻣﺘﻄﻠﺒﺎﺗﻚ‬ .‫ﻗﺒﻞ ﺍﺳﺘﻌﻤﺎﻝ ﻣﻜﻴﻔﺔ ﺍﻟﻬﻮﺍﺀ، ﻳﺮﺟﻰ ﻗﺮﺍﺀﺓ ﻛﺘﻴﺐ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ﻫﺬﺍ ﺑﻌﻨﺎﻳﺔ ﻭﺍﻻﺣﺘﻔﺎﻅ ﺑﻪ ﻟﻠﻤﺮﺍﺟﻌﺔ ﻓﻲ ﺍﻟﻤﺴﺘﻘﺒﻞ‬ .‫ﻫﺬﺍ...
  • Page 48 ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬ ‫ﺟﻤﻴﻊ ﺍﻷﺑﻌﺎﺩ ﻫﻲ ﺑﺎﻟﻤﻠﻴﻤﺘﺮ ﻣﻢ‬ MADE IN MALAYSIA ‫ﺍﻷﺑﻌﺎﺩ‬ ‫ﺍﻟﻤﻮﺩﻳﻞ‬ 1030 R(Y)NV30 ٣...
  • Page 49 ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬ SCREW SCREW SCREW SCREW SCREW ‫ﻣﻦ ﺧﻼﻝ ﺛﻘﺐ ﺍﻟﺠﺪﺍﺭ‬ WM3035J WM3035J ‫ﻣﻢ‬ ‫ﻗﻄﺮ‬ SCREW SCREW ‫ﻣﻜﺎﻥ ﺧﺮﻃﻮﻡ‬ ‫ﻃﺮﻑ ﺍﻧﺒﻮﺏ ﺍﻟﻐﺎﺯ‬ ‫ﻃﺮﻑ ﺍﻧﺒﻮﺏ ﺍﻟﺴﺎﺋﻞ‬ ‫ﺍﻟﺘﺼﺮﻳﻒ‬ ‫ﻟﻮﺣﺔ ﺍﻟﺘﺮﻛﻴﺐ‬ FTD30/36 ‫ﺟﻤﻴﻊ ﺍﻷﺑﻌﺎﺩ ﻫﻲ ﺑﺎﻟﻤﻠﻴﻤﺘﺮ ﻣﻢ‬ ‫ﺍﻷﺑﻌﺎﺩ‬ ‫ﺍﻟﻤﻮﺩﻳﻞ‬ 1289 FT(Y)NV30 ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬ ‫ﺟﻤﻴﻊ...
  • Page 50 ‫ﺍﻟﺮﺳﻢ ﺍﻟﺘﺨﻄﻴﻄﻲ ﻭﺍﻷﺑﻌﺎﺩ‬ ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬ ‫ﺗﺒ ﻴ ﹼﻦ ﺍﻟﻌﻼﻣﺔ‬ ‫ﺍﺗﺠﺎﻩ ﺍﻻﻧﺎﺑﻴﺐ‬ ‫ﺍﻟﺨﻠﻒ‬ ‫ﺍﻟﺨﻠﻒ‬ ‫ﺍﻟﻴﺴﺎﺭ‬ ‫ﺍﻟﻴﻤﻴﻦ‬ ‫ﺍﻟﻤﻨﻈﺮ ﺍﻟﻌﻠﻮﻱ‬ ‫ﺻﻔﻴﺤﺔ ﺍﻻﺳﻢ‬ ‫ﻣﺴﺘﻘﺒﻞ ﺍﻻﺷﺎﺭﺓ‬ ‫ﺑﻠﻮﻙ ﺍﻟﺘﻮﺻﻴﻞ ﻣﻊ‬ ‫ﺍﻻﺳﻔﻞ‬ ‫ﺍﻻﺳﻔﻞ‬ ‫ﺗﻮﺻﻴﻞ ﺍﻻﺭﺿﻲ‬ ‫ﺍﻟﻤﻨﻈﺮ ﺍﻟﺠﺎﻧﺒﻲ‬ ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻣﻔﺘﺎﺡ‬ ‫ﺷﻖ ﺍﻟﺘﻬﻮﻳﺔ‬ ‫ﺍﻳﻘﺎﻑ‬ ‫ﺗﺸﻐﻴﻞ‬ ‫ﺑﺮﻏﻲ ﺗﺜﺒﻴﺖ ﺍﻟﺸﺒﻜﺔ ﺍﻻﻣﺎﻣﻴﺔ‬ ‫ﺍﻟﺪﺍﺧﻞ‬...
  • Page 52 ‫ﻛﺘﻴﺐ‬ ‫ﺍﻟﺘﺮﻛﻴﺐ‬ ‫ﺍﻟﺴﻠﺴﻠﺔ ﺍﻟﻤﻨﻔﺼﻠﺔ‬ R410A ‫ﺍﻟﻤﻮﺩﻳﻞ‬ RNV20JVAK FTNV20JVAK RNV25JVAK FTNV25JVAK RNV30JVAK FTNV30JVAK ‫ﻋﺮﺑﻲ‬ ‫ﻛﺘﻴﺐ ﺍﻟﺘﺮﻛﻴﺐ‬ RYNV20JVAK FTYNV20JVAK ‫ﺍﻟﺴﻠﺴﻠﺔ ﺍﻟﻤﻨﻔﺼﻠﺔ‬ R410A RYNV25JVAK FTYNV25JVAK RYNV30JVAK FTYNV30JVAK RS20JVAK FTS20JVAK RS25JVAK FTS25JVAK RYS20JVAK FTYS20JVAK RYS25JVAK FTYS25JVAK IM-5WMJ(R)-0714(2)-DAIKIN(SASO) ‫ﺭﻗﻢ ﺍﻟﺠﺰﺀ‬ R08019040624B :...