2 Model Nomenclature

CL 024 – 1 VT C – L L T P D A – X A G X X X X X X 7 X X X X 1 X X X X S B A
1-2 3-5 6 7 8-9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
MODEL:
CL
NOMINAL
CAPACITY:
007, 009, 012, 015,
018, 024, 030, 036,
042, 048, 060, 070
ELECTRICAL
CONFIGURATION:
1 —
208–230/60/1
2 —
277/60/1
3 —
208–230/60/3
4 —
460/60/3
5 —
575/60/3
CABINET CONFIGURATION:
HZ —
Horizontal
VT —
Vertical
COAX OPTIONS:
C —
Copper
N —
Cupro-nickel
WATER CONNECTION:
A —
Front-Right Water
L —
Front-Left Water
RETURN AIR CONFURATION:
L —
Left
R —
Right
DISCHARGE AIR LOCATION:
T —
Top
S —
Straight Through
E —
End
FAN/MOTOR OPTION:
A —
Constant Airflow ECM
P —
PSC
T —
Constant Torque ECM
AIR COIL:
U —
Uncoated
D —
DuoGuard
REVISION LEVEL:
A —
Current
ELECTRIC HEAT:
X —
None
A —
5 kW
B —
7.5 kW
C —
10 kW
CABINET CONSTRUCTION:
A —
G90 Steel / 1/2" 1.5 LB Dual-Density Fiberglass
C —
G90 Steel / 1/2" Closed-Cell Foam
D —
G90 Steel / 1/2" 1.5 LB Dual-Density Fiberglass, Extra Quiet
F —
G90 Steel / 1/2" Closed-Cell Foam, Extra Quiet
2 —
G90 Steel / 1/2" Closed-Cell Foam, 2% Air Leakage
3 —
G90 Steel / 1/2" Closed Cell Foam, Extra Quiet, 2% Air Leakage
APPLICATION:
G —
Extended Range (Geothermal)
NOTE: Not all options are available on all models.
Fig. 1 Model Nomenclature
CL Series Heat Pumps — 8733838716 (2024/05)
Model Nomenclature
CODE STRING LEVEL:
A —
Revision
CHANNEL:
B —
Bosch
STANDARD/SPECIAL:
S —
Standard
A —
Special #1
AGENCY OPTIONS:
X —
Standard, 5k SCCR
G —
100kA SCCR
E —
5k SCCR, Single-Point Power Electric Heat
D —
5k SCCR, Dual-Point Power (Fire Alarm Relay)
NOT USED:
X —
None
DRIVE SPEED (MC ONLY):
X —
N/A
MOTOR HP/QTY (BELT DRIVE ONLY)
X —
N/A
AIR FILTRATION:
1 —
1" Throwaway - 2-Sided Filter Rack (Side Access)
2 —
MERV13 - 4" 4-Sided Filter Rack (Side Access)
4 —
MERV8 - 2" 4-Sided Filter Rack (Side Access)
5 —
MERV13 - 2" 4-Sided Filter Rack (Side Access)
A —
1" Throwaway - 2-Sided Filter Rack (Bottom Access)
B —
MERV13 - 4" 4-Sided Filter Rack (Bottom Access)
D —
MERV8 - 2" 4-Sided Filter Rack (Bottom Access)
E —
MERV13 - 2" 4-Sided Filter Rack (Bottom Access)
NOT USED:
X —
None
ECONOMIZER:
X —
None
E —
Economizer with 3-Way Valve and Controls
WATER-FLOW CONTROL OPTIONS:
X —
None
2 —
2-Way Solenoid Valve
3 —
MeasureFlow (3 GPM/Ton)
4 —
2-Way Solenoid + MeasureFlow
6 —
Water Regulating Valve Connection
H —
Flow Proving Switch (DPS)
CONTROLS:
X —
Standard
M —
DDC - Multi-Protocol (BacNET, Modbus, N2)
TRANSFORMER:
1 —
100 VA
5 —
50 VA
7 —
75 VA
REFRIGERATION:
X —
None
H —
Hot Gas Reheat - On/Off
B —
Hot Gas Bypass
C —
Hot Gas Bypass with Hot Gas Reheat
S —
Straight Cool
ELECTRICAL OPTIONS:
X —
As Default for Non-Used Electrical Codes
B — Blower Monitor Relay
L —
Leak Sensor
K —
Fire Alarm Relay/Dual Power
A —
EMS relay
C —
Compressor Monitor Relay
E —
Pump/Valve Relay
G —
Boilerless Control
J —
Disconnect Switch
M —
Wire Transformer to 208 Volts
| 7