10.ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance from the
power supply.
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. If
other types of gas are to be used, the nozzles must be replaced and the primary
air must be adjusted.
In order to replace the nozzles and adjust the burners, the hob top must be
removed as described below.
10.1 Removing the hob top
After having removed the pan
stands, extract all knobs by lifting
them upwards.
Lift all the burner components off
the hob.
Remove the screws fastening the
top and the plates corresponding to
each burner zone.
For 70cm models only, the two
back
removed.
22
Instructions for the installer
screws
must