Lift the hob top upwards.
10.2 Adjustment for LPG
Loosen screw A and push support B all the way. Using a a double head, remove
nozzle C and replace it with the appropriate nozzle, following the instructions in
the tables for the type of gas to be used. The nozzle tightening torque must be
no more than 3 Nm. Reposition support B so that nozzle C is covered perfectly.
Move the Venturi tube D to adjust the air flow until distance "X" is reached as
indicated in the table in paragraph "10.4 Primary air adjustment" and then
secure the tube by means of screw A. After the adjustments have been carried
out, restore the seals with sealing wax or equivalent material.
Burner
Auxiliary (1)
Semi-rapid (2)
Rapid (3)
Reduced Rapid (4)
Ultra-rapid (5)
Internal (6)
Double crown
External (6)
Instructions for the installer
Rated
heating
capacity
(kW)
1.1
1.7
3.1
2.6
3.5
1.0
3.2
LPG – G30/G31 28/37 mbar
Nozzle
Reduced
diameter
capacity
1/100 mm
(W)
48
400
62
500
85
1000
76
750
87
1600
48
400
85
1400
Capacity
Capacity
g/h G30
g/h G31
80
79
124
121
225
221
189
186
256
250
73
71
233
229
23