THINGS YOU SHOULD KNOW
Freedom 458 Series
with Branch Circuit Rated Breakers
Branch Circuit Breakers
20 Amp
15 Amp
Integral Branch Circuit Rated Breakers
Models 15D&20D
Inverter/Charger
Branch Circuit
Rated Breaker
INPUT
Units with integral branch circuit rated
breaker protection require a branch circuit
rated breaker at the input only. The output to
two branch loads may be connected directly
at the unit output.
NOTE: The INPUT branch rated circuit
breaker may be at the source of AC power
(such as shorepower or generator, or from a
main AC distribution panel located before
the input of the unit).
Supplemental
Branch Circuit Rated Breakers
Inverter/Charger
Branch Circuit
Rated Breaker
INPUT
*Models 25 and 30 include a
second input and output
6
Shown:
Freedom 20D
81-2022-12
To LOADS
Models
10,15,20,25,30
Branch Circuit
Rated Breaker

Temperature Sensitive Charging

When the supplied battery temperature
sensor is connected to the unit and the
batteries, the charge voltage is controlled
based on battery temperature. The charger
adjusts the charge voltage to the best level,
minimizing water loss in wet cell batteries.
Charge voltage regulation optimizes the bat-
tery life cycle.
TSC Sensor
Battery