Comprehensive Protection
The Freedom X's built-in protection features safeguard your
batteries (from unnecessary drain) such as the low battery voltage
alarm and shutdown and protect equipment such as a configurable
AC transfer speed.
Selectable Low Battery Shutdown: The low battery
n
shutdown for the inverter can be manually selected by the
user from 10.1 to 12.8 VDC (12VDC models) and from 20 to
25.6 VDC (24VDC model).
Low Voltage Shutdown Delay Timer: Configurable from 1
n
to 300 seconds to reduce an unnecessary shutdown of
inverter operation such as during cranking or other brief but
heavy discharge of battery.
Inverter Power Save: The Freedom X can be programmed
n
to automatically turn off after 1 to 25 hours of continued
operation of loads that are under 50 watts. It is designed,
with LBCO (low battery cut off), to prevent the battery from
deep discharge.

Configurable AC Transfer Speed

The Freedom X allows two speed settings for the AC transfer from
Grid Mode to Battery Mode and vice versa which avoids nuisance
resetting of appliances. The normal transfer rate is for common
appliances and the faster transfer rate is designed for more
sensitive digital equipment like a desktop computer.
975-0787-01-01

Overload Alarm and Shutdown

During Battery Mode (also called Inverter Mode), the Freedom X
automatically alerts you if the loads that are connected and
drawing power from the unit are close to approaching the
maximum operating limit. If so, the Freedom X automatically
shuts down when the maximum operating limit is exceeded. See
Troubleshooting Reference on page 72 for precautions.
Over temperature Alarm and
Shutdown
During Battery Mode, the Freedom X automatically alerts you if it
is overheating and approaching the over-temperature shutdown
limit. The Freedom X automatically shuts down when the limit is
exceeded. See Troubleshooting Reference on page 72 for
precautions.

Ignition Control

The Freedom X provides two user-selectable options for ignition
control:
Ignition Auto-on: The Freedom X can automatically turn
n
the inverter on and off in tandem with the vehicle's ignition
circuit or a manually operated remote switch.
Ignition Lockout: The Freedom X features the ability to
n
inhibit the inverter from operating in the absence of a voltage
signal from a vehicle's ignition circuit. This is particularly
useful if the inverter is required to operate only when a
vehicle's engine is running.