Esse-ti HELPY SUPER COMPACT Quick Manual

Esse-ti HELPY SUPER COMPACT Quick Manual

Alarm system for elevators compliant with the european standard
Hide thumbs Also See for HELPY SUPER COMPACT:

Advertisement

Quick Links

Alarm system for elevators
compliant with the European Standard
EN 81-28:2018
HELPY SUPER COMPACT
QUICK GUIDE
7IS-80585 09/02/2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HELPY SUPER COMPACT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Esse-ti HELPY SUPER COMPACT

  • Page 1 Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY SUPER COMPACT QUICK GUIDE 7IS-80585 09/02/2024...
  • Page 2 T1 Terminal blocks T2 Terminal blocks T3 Terminal blocks CODE NAME DIMENSIONS (H x W x D) 5HL-670 Helpy Super Compact 83 x 50 x 15 mm 5HL-680 Helpy Super Compact COP 130 x 65 x 14 mm Page 2 DESCRIPTION...
  • Page 3: Terminal Blocks

    TERMINAL BLOCKS PSTN-line or universal gateway input (2G/3G/4G) PSTN-line or universal gateway input (2G/3G/4G) Alarm input Common terminal for input AL1 Alarm input 2 (freely programmable; factory default: reset input) Alarm input 3 (freely programmable; factory default: filter input) Power supply input (10 Vdc - 30 Vdc) —...
  • Page 4 CONNECTING THE EMERGENCY CALL BUTTONS It is possible to connect voltage free contact pushbuttons or powered pushbuttons. Note: in order to use inputs AL2 and AL3, they must be configured as alarm inputs with the “Inputs setting” programming (codes 390 or 55). ➢...
  • Page 5 Powered pushbutton (12-24 Vdc) – 2 solutions CONNECTING THE EMERGENCY CALL BUTTONS Page 5...
  • Page 6 CONNECTING THE FILTER INPUT ➢ Connect, following one of the diagrams shown below, the filter contact. Page 6 CONNECTING THE FILTER INPUT...
  • Page 7 The RECEIVED ALARM INDICATOR LIGHT (green) switches on when communication is established. Helpy Super Compact comes with built-in indicator lights. It is also possible to connect external indicator lights. Note: the outputs OUT1 and OUT2 are configured as indicator light outputs with the “Outputs setting”...
  • Page 8: Other Connections

    OTHER CONNECTIONS ONNECTING THE TELEPHONE LINE PSTN line or universal gateway (2G/3G/4G) ➢ Connect the telephone line to LTI terminals. ONNECTING THE RESET CONTACT ➢ Connect the reset contact as per one of the modes shown in the table: C2-3 TERMINAL RESET CONTACT CONNECTED TO: TERMINAL BLOCKS...
  • Page 9: Connecting The Microphone

    ONNECTING THE MICROPHONE Helpy Super Compact comes with a built-in speaker unit. A cable with microphone can also be connected to the Helpy Super Compact. ➢ Connect a cable with microphone to MIC2 and terminals. – ONNECTING THE POWER SUPPLY ➢...
  • Page 10: Wiring Diagram

    WIRING DIAGRAM Page 10 WIRING DIAGRAM...
  • Page 11 MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING Note: if the keypad is not present, please use another programming method (see the next chapter). ➢ Access to programming: dial on the keypad. The programming activated message will be heard. ➢ Program a telephone number for the emergency-call alarm: dial <telephone number>...
  • Page 12: Resetting The Alarm

    mode: two-way communication established after input of “Communication activation” code ➢ Answer by the called party. The voice messages will be heard. ➢ Press to speak with the trapped person. mode: immediate and automatic two-way communication (no messages) ➢ Answer by the called party. ➢...
  • Page 13: Basic Programming

    < INSTALLER or OPERATOR PASSWORD > PROGRAMMING (factory default: SOURCE RECEIVER emergency- — call button battery USER alarm * periodic automatic test ESSE-TI call * … — (X..X = telephone number, TELEPHONE (position — (only with max. 20 NUMBERS from 01 to 4G.VoLTE)
  • Page 14: Listen To Messages

    BASIC PROGRAMMING DELETE A TELEPHONE (position from 01 to NUMBER (INST) WEEKDAY SUNDAY MONDAY TUESDAY DATE * (dd) (mm) (yy) (INST) WEDNESDAY THURSDAY * to be FRIDAY reprogrammed in SATURDAY case of turn off TIME * (hhmm from 0000 to 2359) (INST) identification message...
  • Page 15 Set the telephone number for notification: BATTERY TONE 201 XX 11 Y <telephone number> # (INST) where XX= position (from 01 to 24) Y= notification mode (2= user, 3= Esse-ti, 4= CLI, 5= SMS only with 4G.VoLTE, 6= P100) daily Type of frequency hourly (days, from 1 to 9;...
  • Page 16: Advanced Programming

    BASIC PROGRAMMING LISTEN TO THE PROGRAMMING (programming code prefix) AGAIN (INST) RESTORE FACTORY SETTINGS (INST) Advanced programming ADVANCED PROGRAMMING CHANGE THE INSTALLER … PASSWORD “0” (old) (new) (new) (INST) CHANGE THE OPERATOR … PASSWORD “1” (old) (new) (new) (INST) INPUTS input NORMALLY type...
  • Page 17: Input Configuration

    (INST) 3= Esse-ti 4= CLI 6= P100 - if receiver 3, set the Esse-ti protocol ID: 222 YYYYYYYYYY - if receiver 6, set the P100 protocol ID: 223 ZZZZZZZZ# - if receiver 6, customize the P100 protocol codes using the e-stant software (programming code 203) Note: AL2 and AL3 are automatically configured as normally closed;...
  • Page 18 ADVANCED PROGRAMMING BEEP ENABLING beep disabled WHEN PUSHBUTTON IS PRESSED beep enabled (INST) ST-Power not connected ST-POWER CONNECTION (INST) ST-Power connected NO EXTERNAL disabled alarm POWER SUPPLY ALARM * enabled alarm with XX minutes delay (INST) (from 01 to 99) * only with ST-Power EXTERNAL disabled notification...
  • Page 19 ADVANCED PROGRAMMING CALL DELAY (seconds of waiting after the courtesy message AFTER COURTESY before sending the call, from 0 to 9; MESSAGE factory default 3) (INST) PLAYBACK OF never “COMMUNICA- TION ACTIVA- TED” MESSAGE only in case of remote connection WHEN THE SPEAKER UNIT IS ACTIVATED...
  • Page 20 ADVANCED PROGRAMMING LANGUAGE (INST) (language: 00 Italian, 01 English, 02 German, (available 03 French, 04 Polish, 05 Portuguese, languages may 06 Russian, 07 Spanish, 09 Czech, 10 Croatian, vary depending on 11 Greek, 13 Slovenian, 19 Chinese, model or country of 21 Flemish, 23 Swedish, 26 Slovak) installation) MULTI-...
  • Page 21 ADVANCED PROGRAMMING WAITING TIME BETWEEN EMERGENCY (from 0 to 9; 0=30 seconds, 1=60 seconds, 2=90 CALLS TO THE seconds, …, 9=300 seconds) SAME NUMBER (INST) WAITING TIME BETWEEN TECHNOLOGICAL (minutes, from 01 to 99; OR TEST CALLS 00=30 seconds, factory default 02) TO THE SAME NUMBER (INST)
  • Page 22 ADVANCED PROGRAMMING given alarm received alarm 800 ms activation by code 823/824 active as long as the emergency alarm progresses output OUTPUTS active as long as the buttons are pressed SETTING OUT1 (INST) active for telephone line failure OUT2) active for low battery active as long as the buttons are pressed even with filter active factory default:...
  • Page 23: Remote Programming

    GO can be downloaded from an official store (Google Play or App Store). Local programming via e-stant software It is possible to program Helpy Super Compact via computer by using an USB- C cable and the dedicated e-stant software. e-stant software also allows to:...
  • Page 24 EXTERNAL CALLS END THE CALL Use remotely with Helpy Super Compact at rest ➢ Call Helpy Super Compact and wait for a response. ➢ Listen to the elevator identification message, if present. ➢ Dial to speak with the speaker unit.
  • Page 25: Device Status Led

    SIGNALS Device status LED Normal operation (no alarm) Alarm Voice connection Low battery (max. 1-hour operation in idle state) Absence of telephone line Button failure SIGNALS Page 25...
  • Page 26 Given alarm indicator light (yellow) Alarm Received alarm indicator light (green) Voice connection Missed test call notification (EN 81-28:2018) The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call. The flashing sequence ends after the next successful test call or emergency call.
  • Page 27: Eu Declaration Of Conformity

    EU DECLARATION OF CONFORMITY Hereby, Esse-ti S.r.l. declares that the equipment type Helpy Super Compact is in compliance with Directives 2014/30/EU - 2014/33/EU - 2014/35/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://esse-ti.it/dichiarazioni-di-conformita...
  • Page 28 Esse-ti S.r.l. Via G. Capodaglio, 9 62019 Recanati (MC) – ITALY +39 071 7506066 www.esse-ti.it support@esse-ti.it...

This manual is also suitable for:

5hl-6805hl-670

Table of Contents