Esse-ti HELPY COMPACT-Q Quick Manual

Esse-ti HELPY COMPACT-Q Quick Manual

Alarm system for elevators compliant with the european standard en 81-28:2018

Advertisement

Quick Links

Alarm system for elevators
compliant with the European Standard
EN 81-28:2018
HELPY COMPACT-Q
QUICK GUIDE
To download User guides in other languages
please scan the QR-code or visit
https://www.esse-ti.it/en/manuals
19/05/2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HELPY COMPACT-Q and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Esse-ti HELPY COMPACT-Q

  • Page 1 Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY COMPACT-Q QUICK GUIDE To download User guides in other languages please scan the QR-code or visit https://www.esse-ti.it/en/manuals 19/05/2021...
  • Page 2 DESCRIPTION Autodialer specifically designed for installation on car roof. A Built-in loudspeaker connector B Device status LED C Reset pushbutton D Serial port for PC connection E Alarm pushbutton F Received alarm indicator light G Pushbutton connection cable (connect to T) H Micro SD Card slot Jumpers J16 / J17 L Connector not used...
  • Page 3: Terminal Blocks

    TERMINAL BLOCKS PSTN-line or universal gateway input PSTN-line or universal gateway input Ground terminal for PSTN-line Output for domestic telephone line Output for domestic telephone line Local telephone — Negative RL1 NO Relay (normally open contact) RL1 NC Relay (normally closed contact) RL1 C Relay (common contact) Power supply input (10 Vdc - 30 Vdc)
  • Page 4 CONNECTING THE SPEAKER UNITS Helpy Compact-Q comes with a built-in speaker unit. It is also possible to connect to the Helpy Compact-Q up to 2 passive speaker units or cables with microphone on top and bottom of elevator car.  Make the connections as shown in the table below: HELPY COMPACT-Q MAX.
  • Page 5 CONNECTING THE EMERGENCY CALL BUTTONS The pushbuttons of pit, top and bottom of elevator car can only be connected to AL1 terminal block if they are voltage-free NO. The pushbuttons of pit, top and bottom of elevator car can only be connected to AL2 terminal block if they are voltage-free.
  • Page 6 CONNECTING THE FILTER INPUT It is possible to use a voltage free contact (NO or NC).  Connect, following the diagram shown below, the filter contact. Note: the IN1 input can be configured as NO or NC with the “Inputs normally open/closed”...
  • Page 7 CONNECTING THE INDICATOR LIGHTS Helpy Compact-Q comes with built-in indicator lights. The GIVEN ALARM INDICATOR LIGHT (yellow) switches on after pressing the emergency button to indicate the beginning of the alarm procedure. The RECEIVED ALARM INDICATOR LIGHT (green) switches on when the alarm call is answered.
  • Page 8: Other Connections

    OTHER CONNECTIONS ONNECTING THE TELEPHONE LINE PSTN line or universal gateway (2G/3G/4G)  Connect the ground terminal (indicated by ), to a ground socket in order to increase the PSTN line protection.  Connect the telephone line to LTI terminals. ONNECTING THE LOCAL TELEPHONE ...
  • Page 9: Wiring Diagrams

    WIRING DIAGRAMS WIRING DIAGRAMS Page 9...
  • Page 10: Turning On / Turning Off

     Connect the external (12 Vdc - 30 Vdc) power supply to + and — terminals. Helpy Compact-Q lights up and the device status LED starts flashing. URNING OFF  Disconnect the external (12 Vdc - 30 Vdc) power supply from + and —...
  • Page 11 MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING  Access to programming: lift the local telephone handset and dial The programming activated message will be heard.  Program a telephone number for the emergency-call alarm: dial <telephone number>  Record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location: dial and, after the “Correct”...
  • Page 12: Resetting The Alarm

    mode: two-way communication established after input of “Communication activation” code  Answer by the called party. The voice messages will be heard.  Press to speak with the trapped person. mode: immediate and automatic two-way communication (no messages)  Answer by the called party. ...
  • Page 13 * <Password> #. Pressing longer (10 seconds) Allows to reset the device. By pressing longer, the Helpy Compact-Q will be re-started with no need to disconnect the power supply. Note: it is also possible to reset the device through the code 995*0#.
  • Page 14: Basic Programming

    < INSTALLER or OPERATOR PASSWORD > EXITING THE PROGRAMMING (factory default: SOURCE RECEIVER emergency- — call button battery USER alarms * periodic automatic test ESSE-TI call * … (X..X = — telephone number, (position TELEPHONE max. 20 — — from 01 to NUMBERS digits;...
  • Page 15: Listen To Messages

    BASIC PROGRAMMING DELETE A TELEPHONE (position from 01 to NUMBER (INST) WEEKDAY SUNDAY MONDAY TUESDAY DATE * (dd) (mm) (yy) (INST) WEDNESDAY THURSDAY * to be FRIDAY reprogrammed in SATURDAY case of turn off TIME * (hhmm from 0000 to 2359) (INST) identification message...
  • Page 16 AUTOMATIC TEST automatic test disabled DATA Automatic (INST) automatic test enabled (EN 81-28:2018) test alarm automatic test enabled (EN 81-28:2004) Make a test call manually PROTOCOLS Esse-ti IDENTIFICATION … (identification code) CODE P100 (INST) SPEAKER UNITS loudspeaker microphone VOLUME (from 1 to...
  • Page 17: Advanced Programming

    Advanced programming ADVANCED PROGRAMMING CHANGE THE INSTALLER … PASSWORD “0” (old) (new) (new) (INST) CHANGE THE OPERATOR … PASSWORD “1” (old) (new) (new) (INST) INPUTS NORMALLY input type OPEN/CLOSED (2=AL2 (0=normally closed (INST) 3=IN1) 1=normally open) AL2=alarm input / IN1=filter input AL2=auxiliary input / IN1=filter input AL2=alarm input / IN1=gong input AL2=auxiliary input / IN1=gong input...
  • Page 18: Input Configuration

    (INST) 3= Esse-ti 4= CLI 6= P100 - if receiver 3, set the Esse-ti protocol ID: 222 YYYYYYYYYY - if receiver 6, set the P100 protocol ID: 223 ZZZZZZZZZZ - if receiver 6, customize the P100 protocol codes using the e-stant software (programming code 203) Note: AL2 and IN1 are automatically configured as normally closed;...
  • Page 19: Filter Bypass

    ADVANCED PROGRAMMING BUILT-IN disabled alarm SPEAKER UNIT DIAGNOSTIC ALARM enabled alarm (INST) FILTER disabled ACTIVATION (INST/OPER) enabled FILTER BYPASS (seconds, from 15 to 30; 99=no bypass) (INST/OPER) ALARM AI indicator light lit and courtesy message OPERATION WITHOUT AI indicator light unlit and no courtesy message TELEPHONE LINE (INST) AI indicator light lit and no courtesy message...
  • Page 20 ADVANCED PROGRAMMING “PLAY IDENTIFICATION … (from 1 to 3 digits; factory default 5) MESSAGE” CODE (INST) “COMMUNICA- TION ACTIVATION” … (from 1 to 3 digits; factory default 0) CODE (INST) “END ALARM” CODE … (from 1 to 3 digits; factory default 9) (INST) “EXCLUSION”...
  • Page 21 ADVANCED PROGRAMMING CALL CYCLES FOR EMERGENCY CALL (cycles, from 1 to 9; 0=unlimited) ALARMS (INST) CALL CYCLES FOR TECHNOLOGICAL (cycles, from 1 to 9; 0=10 cycles; ALARMS AND factory default 3) TEST CALLS (INST) WAITING TIME BETWEEN EMERGENCY (from 0 to 9; 0=30 seconds, 1=60 seconds, 2=90 CALLS TO THE seconds, …, 9=300 seconds) SAME NUMBER...
  • Page 22: Relay Setting

    ADVANCED PROGRAMMING same behaviour as outputs AI same behaviour as outputs AR door opener RELAY SETTING active as long as the emergency alarm progresses (INST) active as long as the buttons are pressed active for telephone line absence active for low battery RELAY steady-state INTERMITTENCE...
  • Page 23: Remote Programming

    Local programming via e-stant software It is possible to program Helpy Compact-Q via computer by using the USB/serial proprietary cable and the dedicated e-stant software. e-stant software also allows to: - update the firmware of the Helpy Compact-Q - customize the messages of the Helpy Compact-Q - set a micro SD card to use for programming, customizing the messages and updating the firmware of the Helpy Compact-Q.
  • Page 24: Local Use

    EXTERNAL CALLS <TELEPHONE NUMBER> DOOR OPENER RELAY Use remotely with Helpy Compact-Q at rest  Call Helpy Compact-Q and wait for a response.  Listen to the elevator identification message, if present.  Dial to speak with all speaker units.
  • Page 25: Device Status Led

    SIGNALS Device status LED Normal operation (no alarm) Alarm Voice connection Low battery (max. 1-hour operation in idle state) Absence of telephone line Button failure SIGNALS Page 25...
  • Page 26 Given alarm indicator light (yellow) Alarm Received alarm indicator light (green) Voice connection Missed test call notification (EN 81-28:2018) The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call. The flashing sequence ends after the next successful test call or emergency call.
  • Page 27 NOTES EU D ECLARATION OF ONFORMITY Hereby, Esse-ti S.r.l. declares that the equipment type Helpy Compact-Q is in compliance with Directives 2014/33/EU - 2014/53/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://www.esse-ti.it/en/dichiarazioni-di-conformita...
  • Page 28 Esse-ti S.r.l. Via G. Capodaglio, 9 62019 Recanati (MC) – ITALY Tel. +39 071 7506066 Fax +39 071 7506057 www.esse-ti.it support@esse-ti.it...