Lpg Storage; Removing From Storage; Removing From Storage: Propane (Lpg) - Champion CHG3500-DF-P Operator's Manual

3000w dual fuel portable generator
Table of Contents

Advertisement

CHG3500-DF-P - 3000W DUAL FUEL PORTABLE GENERATOR
6. Follow steps 7-11 according to Mid Term Storage.

LPG Storage

Always disconnect the LPG hose from the generator and shut off
the LPG tank for proper storage.
Plug the outlet, usually by a plastic protective cap, if one is
available. Always keep cylinders away from heat.

Removing from Storage

If the generator has been improperly stored for a period longer
than 30 days with ethanol blended petrol in the fuel tank and/
or carburetor, all fuel must be drained and the carburetor
must be thoroughly cleaned of ethanol build up. This process
involves technically advanced tasks. For assistance please call
our Technical Support Team.
If the fuel tank and carburetor were properly emptied of all
ethanol blended Petrol prior to the generator being stored,
follow the below steps when removing from storage.
1. Be sure the engine switch is in the "ENGINE STOP" position.
2. Add Petrol to the generator according to Add Fuel: Petrol.
3. Turn the fuel value to the "Petrol RUN" position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking Petrol. If any leaks are found, the carburetor will
need to be disassembled and cleaned or replaced. If no Petrol
leaks are found, turn the fuel dial to the "ENGINE STOP"
position.
5. Check engine oil level and add clean, fresh oil if needed. See
Oil Specifications for proper oil type.
6. Check and clear air filter of any obstructions such as bugs or
cobwebs. If necessary, clean air filter according to Cleaning
the Air Filter.
7. Start the generator according to Starting the Engine.

Removing from Storage: Propane (LPG)

Upon removal from storage, inspect LPG fittings and hose lines for
leaks before using the generator.
If there is a strong smell of LPG: Close valve on the cylinder.
Check all connections for leaks by wetting the fittings with a
solution of soap and water. Bubbles which appear or bubbles
which grow indicate that a leak exists. Do not smoke or light a
cigarette, or check for leaks using a match, open flame source
or lighter. Contact a qualified technician to inspect and repair
an LPG system if a leak is found, before using the generator.
NOTICE
WARNING
29