2. Allow the engine to run for several minutes to get up to
temperature.
3. Make sure all circuit breakers are set to the run position.
4. Plug in and turn on the first item. It is best to attach the item
with the largest load first.
5. Allow the engine to stabilize.
6. Plug in and turn on the next item.
7. Allow the engine to stabilize.
8. Repeat steps 5-6 for each additional item.
Never exceed the specified capacity when adding loads to the
generator.

Stopping the Engine

1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let generator run at no-load for several minutes to stabilize
engine and alternator temperature.
3. Press the engine switch to the "OFF" position.
Petrol
4. Turn the fuel valve to the "OFF" position.
NOTICE
Propane
5. If operating on LPG, close valve on LPG cylinder.
For safety, this generator will not stop using the ON/OFF
switch on LPG/Propane, the gas cylinder has to be turned OFF
(valve fully closed) to stop the generator.

Moving the Generator

– NEVER lift or carry the generator using the folding handle.
– NEVER tilt sideways while moving the generator.
– ALWAYS place the generator on its wheels in the upright
position.
– ALWAYS turn the generator off and ensure the fuel valve is
closed.
– ALWAYS make sure engine and muffler are cooled down
before the generator can be handled safely (typically 30
minutes).
Failure to follow these instructions could result in personal
injury or damage to the generator resulting in voiding any
warranty.