Culligan
Iron Cleer
®
Control Valve
Timer
Overall Conditioner Height
Media Tank Dimensions (D
x H)
Filter Media Type
Underbedding
G-50
Cullsan U
Capacity
1
Freeboard
2
Max. Clear Water (Soluble)
Iron
Max. Hydrogen Sulfide
Minimum Alkalinity
pH
Service Flow @ Pressure Drop (Clean Bed)
Normal
Maximum
3
Operating Pressure
Operating Temperature
Electrical Requirements
Power Consumption,
Continuous/Maximum
Drain Flow, Maximum
Regeneration Time
Backwash
Fast Rinse
Capacity based on 4 gpm and 10 mg/L of dissolved iron.
1
Measured from top of media bed to top of inlet fitting.
2
Max flow rates & pressure drop characteristics have not been validated by the Water Quality
3
Association.
The max specified flow rate at which the system will deliver treated water as validated by the Water
Quality Association is defined as service flow.
Filters
®
10" Iron Cleer
1" 5-cycle reinforced
thermoplastic
Electro-mechanical
67"
2 ea. 10" x 54" tanks
1.0 cu. ft. birm
35 lbs.
25 lbs.
1400 gallons
21"
10 ppm
5.0 ppm
100 ppm
7.0 - 8.5
5 gpm @ 9 psi
6 gpm @ 9 psi
20-60 psi
33-120° F (1-48° C)
120 Volts/60 Hz
3 watts/203 watts
10 gpm (5.5 gpm min. required) 10 gpm (8.0 gpm min. required)
5 - 20 minutes
5 - 20 minutes
12" Iron Cleer
1" 5-cycle reinforced
thermoplastic
Electro-mechanical
65"
2 ea. 12" x 52" tanks
1.5 cu. ft. birm
35 lbs.
25 lbs.
2000 gallons
18"
10 ppm
5.0 ppm
100 ppm
7.0 - 8.5
7 gpm @ 10 psi
9 gpm @ 14 psi
20-60 psi
33-120° F (1-48° C)
120 Volts/60 Hz
3 watts/203 watts
5 - 20 minutes
5 - 20 minutes