4.4 Main components

UniGear 500R switchgear is equipped with a Vmax
removabl vacuum circuit -breaker.
The circuit-breaker is connec ted in series with a
three-position "off-load" disconnector (ON – OFF –
EARTH).
Circuit-breaker
disconnector are mechanically interlocked.
4.4.1. Vmax
circuit-breaker(Figure 32)
The Vmax circuit -breaker, is a vacuum circuit-breaker
with mechanical operating mechanism. It is installed in
the circuit-breaker/cable compartment
(Figure 24)
(zone C) in series with the off load three-
position
disconnector.
mechanically
interlocked
disconnector to prevent dangerous or inadvertent
operation.
The circuit-breaker can be tripped either mechanically
(with push-buttons 1 and 2) or electrically, according
to the interlocking logics.
On request, the circuit -breaker can be equipped with
an electric geared motor for charging the operating
springs. It is always possible to use the lever (5) to
manually charge the operating springs.
For detailed information, please see the relevant
technical
catalogue
installation and service manual no. 1VCD600189.
F i g u re 32: Vmax ci rcu i t - b rea ker.
1
Closi ng pus h but t on
2
O penin g pus h but t on
3
Ind icat or f or circuit - br eak er op enin g clos ing
4
Ind icat or f or sprin gs char ged or discharg ed
5
Lev er t o man ual l y charg e oper at in g spri ngs
6
O perat ion c ount er
16
and
three -position
(Figure
The
circuit-breaker
with
the
three -position
no.
1VCP000169
and
4.4.2. Three-position disconnector
The
manually
disconnector is located in the busbar compartment
and has three positions
ON: Circuit-breaker connected to the busbar system.
OFF: Circuit-breaker isolated from the busbars and
from earth.
EARTH: Circuit-breaker connected to earth.
These positions, visible on an indicator located on the
23),
front of the switchgear
(Figure
35).
For
is
disconnector see
The
IEC
version
inspection window which allows to verity the position
of the contacts of the threeposition disconnector
(Figure
34).
the
F i g u re 33: Ci rcu i t - b reaker co n n ected to earth .
F i g u re 34: Ci rcu i t - b reaker i so l ated fro m th e bu sb ars an d
fro m earth .
(Figure 33)
operated
"off -load"
(Figure
35):
(Figure
92)(D) are shown in
operation
of
the
(chapter
7.2).
cubicle
is
fitted
three-position
three -position
with
a
front

Advertisement

Table of Contents
loading

Table of Contents