Connections - Westinghouse WFE542 User Manual

540mm and 600mm slot-in upright range cooker
Hide thumbs Also See for WFE542:
Table of Contents

Advertisement

CONNECTIONS

Wiring connection for gas cooker
To allow for disconnection of the appliance after
installation, the plug must be accessible after installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Installing the gas cooker gas connection
Read these points before connecting to the gas supply:
The cooker inlet connection point has a ½" BSP
external thread. See diagram below.
An NG regulator or a LPG/Propane test point fitting
is supplied.
It is recommended to fit the regulator or test point
fitting to the appliance connection point, then fit
either hard piping or a high level flexible connection
(AS/NZS 5601.1 clauses 5.9 and 6.10.1.9) which is then
attached to the consumer hard piping.
Ensure installation allows withdrawal of appliance.
Operation on universal LPG/propane
1.
The appliance inlet fitting provided MUST be
orientated so that the pressure nipple is accessible.
2.
The inlet fitting has ½" BSP internal thread at the inlet
and outlet.
10
CONNECTIONS
Restraining device
anchor points
Gas connection
point
175mm
650mm
Operation on SNG (WFG612 models only)
If the cooker is to be used with SNG, then the grill
burner MUST be modified by the replacement of the
shutter, which fits into the throat of the grill burner.
A conversion kit can be obtained by contacting the
Customer Care Centre.
Grill deflector
Grill shutter
WARNING
WARNING
Disconnect electric power before removing control panel.
1.
Remove the control panel.
2.
Remove the 2 screws from grill deflector (refer to
diagram above)
3.
Remove the existing NG shutter securing screw (refer
to diagram above) and slide upwards to disengage
from grill burner.
4.
Slide the SNG shutter into position and secure
with screws.
Testing the gas cooker
WARNING
WARNING
You MUST test the cooker after installation, before you
hand it over to the customer.
You MUST have a manometer and a connecting tube.
650mm

Advertisement

Table of Contents
loading

Table of Contents