WIRING REQUIREMENTS
The cooker MUST be installed in compliance with:
Wiring connections in AS/NZS 3000 Wiring Rules
Local regulations, municipal building codes and other
statutory regulations
For New Zealand Only:
The cooking range must be connected to the supply
by a supply cord fitted with the appropriately rated
plug that is compatible with the socket-outlet fitted
to the final sub-circuit in the fixed wiring that is
intended to supply this cooking range.
Data plate
gives information about rating
is located behind the bottom of the
oven door
A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS 3000 -
Clause 4.7.1).
Wiring MUST be protected against mechanical failure
(AS/NZS 3000 - Clause 3.9).
Disconnection in the fixed wiring must occur in
accordance with the AS/NZS3000 wiring rules.
The cooker MUST be properly earthed.
This range must be connected with cable of 75°C
rating minimum.
This product has passed the insulation resistance test
after manufacture. If the resistance reading is low at
installation, it is probably caused by moisture from
the atmosphere being absorbed by the elements
after the range has been produced. (Pass at 0.01MΩ
AS/NZS 3000 Wiring Rules Clause 8.3.6.2).
NOTE: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
TIPS & INFORMATION
TIPS AND INFORMATION
Before you cook in your new oven it is important that
the protective oils used in the manufacture of the
product be removed.
Make sure that the room is well ventilated (to allow
smoke to escape).
New appliances can have an odour during first use. It
is recommended to 'run in' the oven before cooking
for the first time Operate the oven(s), empty, at a
temperature of 180°C for approximately 30 minutes.
For appliances with a separate grill, run the grill on
maximum for 15 minutes WITH GRILL DOOR OPEN
Please ensure that the room is well ventilated
during this process.
MODEL
TOTAL
TOTAL
WATTAGE
CURRENT
(KW)
(AMPS)
WFE642
8.7
36.3
WFE647
10.5
43.8
WFE547
10.5
43.8
CONNECTING TO SERVICES AND
COMMISSIONING
This appliance must be installed by an authorised person,
according to all codes and regulations of:
Electrical supply connection
Hard wiring detail (WFE547, WFE642 and WFE647
models only)
1.
2.
3.
4.
RATED POWER INPUT
CABLE
MINIMUM
SECTION
TEMP.
(MM2)
RATING (°C)
2.5
75
4.0
75
4.0
75
Electrical supply authorities.
Building regulations.
Local government and council authorities.
AS/NZS 5601.1 (particular attention to clause 6.10.1
and figure 6.3 on page 97, and clause 6.10.1.11).
AS/NZS 3000 (particular attention to clause 4.7.1
and clause 3.9).
WFE619 and WFE517 models are fitted with
a 20-Amp service cord.
WFE616 and WFG617 models are fitted with
a 10-Amp service cord.
Remove terminal cover plate from rear panel
of appliance.
Fit wires through hole in cover plate and make
connections to terminals.
Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
Replace cover plate onto rear panel.
MODEL
TOTAL KW
WFE547
10.5
WFE642
8.7
WFE647
10.5
Plastic clips
Plastic clip
securing points
A1 KW
A2 KW
4.1
6.4
2.3
6.4
4.1
6.4