Should a machine under test be rejected for any reason requiring the removal of any mechanical part that
could affect the machine's electrical characteristics, or if any electrical components are repaired or replaced,
the machine must be retested.
Input Voltage
400Vac/3ph/50Hz
Output current range
Maximum Open Circuit Voltage
Input Voltage
400Vac/3ph/50Hz
Output current range
Maximum Open Circuit Voltage

RETEST AFTER REPAIR

Machine input and output
CITOTIG 315DC
Input Current
16.9A
CITOTIG 415DC
Input
Current
35A
65
Rated Output
270A - 30,8V@40% Stick
300A - 22V@40% TIG
5-270A Stick
5-300A TIG
65Vdc (CE model)
Rated Output
400A – 36V@35% Stick
400A – 26V@35% TIG
5 - 400A
65Vdc (CE model)