Setup menu
The setup menu contains more parameters that are
hidden from the main control panel functionality.
To enter the Setup menu:
Push and hold "SEL" and "MODE" pushbuttons
+
Keep "SEL" + "MODE" pushed until the displays show
"SET UP"
Then release the SEL" pushbutton
now is shown the option
number "00"
01  99
Select the desired option: on the left display is shown the
option number
then press "SEL" to confirm
ON / OFF
ON / OFF (or 1 / 2 / 3 / 4 only for option 40)
Now enable, disable or change the option value: on the
right display is shown the option status
Save the desired option by pressing the "SEL"
pushbutton
To exit the setup menu select the 00 option and keep
the SEL button pushed for 5 seconds until normal
operation is resumed.
List of menu options
To change a setting push SEL, then rotate the
encoder (Output Current Knob) to modify the setting,
and push SEL again to confirm the new value.
Error Codes and troubleshooting.
If an error occurs, turn Off the machine, wait for a few
seconds, then turn ON again. If the error remains, a
maintenance is required. Please contact the nearest
technical service center or Lincoln Electric and report the
error code displayed on the meter of the Front Panel.
empty display
14
00
Exit point
01
2-step restart
02
4-step restart
10
Spot welding
11
Spot fixed time
20
Bi-Level
30
Foot Pedal
40
Arc start strength
99
Reset to factory default
Error code table
Input out of range
LED is blinking
Indicates that an Input Voltage Overrange
01
protection is active; the Machine restarts
automatically when the Input Voltage returns
in the correct range.
Inverter voltage lock out
LEDs blink alternatively.
Indicates that an Internal Auxiliary Voltage
fault condition is detected.
06
To restore the machine:
Turn OFF then ON the Mains Switch to
restart the machine.
Fan fault
The cooling fan is blocked or faulty.
To restore the machine:
Turn OFF the Mains Switch then and
check if the fan is being blocked by
something that stops the blades.
WARNING
DO
NOT
OPEN
Perform the check through the air inlet
10
louvers placed in the machine rear side.
DO
NOT
INTRODUCE
INSIDE OF THE LOUVERS! Danger of
electric shock.
Turn ON the Mains Switch to restart the
machine and make a short weld, in order
to verify that the fan is restarted.
If the fan remains inactive a maintenance
from a Service is necessary.
Water cooler fault
Cooler fluid is not correctly flowing through
11
the torch. See the water cooler instruction
manual for more details.